Hardware
16
Figure 1.1
Intel
®
RAID Controller SRCS16 Components
1.3.2
Configuration on Disk
Configuration on Disk saves configuration information both in NVRAM on the Intel
®
RAID
Controller SRCS16 and on the disk drives attached to the controller. If the RAID Controller
SRCS16 is replaced, the new controller detects the actual RAID configuration from the
configuration information on the drives.
Note:
Configuration on Disk does not work if you change both the RAID Controller
SRCS16 and the SATA connectors to different connectors on the new RAID
Controller SRCS16. It works only if you make one change at a time.
1.3.3
Drive Roaming
The RAID Controller SRCS16 supports drive roaming across ports on the same controller.
Drive roaming lets a RAID Controller SRCS16 detect the actual RAID configuration,
maintaining the integrity of the data on each disk drive, even if the disk drives have changed
ports and/or target ID.
In addition, the RAID Controller SRCS16 offers enclosure management through the same
protocols used for SCSI Accessed Fault-Tolerant Enclosures (SAF-TE), using an I
2
C
interface to communicate with the storage enclosure processor (SEP). This feature allows you
to use RAID capabilities provided by the RAID Controller SRCS16 adapters in an enclosure
containing your hard drives.
167 mm
56 mm
Port 0 [J7]
Port1 [J8]
Port 2 [J9]
Port 3 [J10]
Port 4 [J11]
Port 5 [J12]
32-bit PCI [J1]
BIOS Enable [J2]
UART Serial I/O [J3]
Write Pending Indication LED [J4]
Serial I/O Connector,
Serial EEPROM [J5]
Serial I2C Connector
(Enclosure Management) [J6]
Reserved
[J17]
3.3V Load
Sharing [J14]
Reserved
[J16]
Battery
Connector
(not used) [J15]
Mode 0 (IOP Reset) [J13]
Speaker
[U6]
Memory
Modules (5)