Intel
®
Server System SR2520SA User’s Guide
31
Installing and Removing Memory
The silkscreen on the board for the DIMMs displays DIMM A1, DIMM A2, DIMM B1,
DIMM B2, DIMM C1, DIMM C2, DIMM D1 and DIMM D2 starting from the center of
the board. See "Memory" for a discussion of the memory requirements and options. See
“Server System References”
for a link to the list of tested DIMMs.
Note: The Intel
®
Server System SR2520SAF/SR2520SAFR only has four DIMM sockets.
Installing DIMMs
To install DIMMs, follow these steps:
1. Observe the safety and ESD precautions in
“Safety Information”
.
2. Turn off all peripheral devices connected to the server. Turn off the server.
3. Disconnect the AC power cord(s) from the server.
4. Remove the system's cover. For instructions, see
“Removing the System Cover”
.
5. Locate the DIMM sockets (see
Figure 21
).