Appendix A: Integration and Usage Tips
Revision
1.3
Intel order number E44588-003
32
8.
Environmental and Regulatory Specifications
8.1
System Level Environmental Limits
The following table defines the system level operating and non-operating environmental limits.
Table 21. System Environmental Limits Summary
Parameter
Limits
Operating Temperature
+10
C to +35
C with the maximum rate of change not to exceed 10
C per hour
Non-Operating
Temperature
-40
C to +70
C
Non-Operating Humidity
90%, non-condensing at 35
C
Acoustic noise
Sound power: 7.0 BA in an idle state at typical office ambient temperature. (23
+/- 2 degrees C)
Shock, operating
Half sine, 2 g peak, 11 mSec
Shock, unpackaged
Trapezoidal, 25 g, velocity change 136 inches/sec (
≧
40 lbs to > 80 lbs)
Shock, packaged
Non-palletized free fall in height of 24 inches (
≧
40 lbs to > 80 lbs)
Vibration, unpackaged
5 Hz to 500 Hz, 2.20 g RMS random
Shock, operating
Half sine, 2 g peak, 11 mSec
ESD*
+/-15 KV except I/O port +/-8 KV per the Intel Environmental test specification
System Cooling
Requirement in BTU/Hr
2550 BTU/hour
*
IMPORTANT NOTES:
The host system with the Intel
®
Server Board S5500BC requires the use of shielded
LAN cable to comply with Immunity regulatory requirements. Use of non-shielded cables may result in the product
having insufficient immunity electromagnetic effects, which may cause improper operation of the product.
8.2
Serviceability and Availability
The system is designed to be serviced by qualified technical personnel only.
The recommended Mean Time To Repair (MTTR) of the system is 30 minutes including
diagnosis of the system problem. To meet this goal, the system enclosure and hardware were
designed to minimize the MTTR.
Following are the maximum times that a trained field service technician should take to perform
the listed system maintenance procedures, after diagnosing the system and identifying the
failed component.