Intel® RAID Adapters RSP3TD160, RSP3MD088, RSP3DD080 and RSP3WD080 Hardware User Guide
24
•
Power Supply voltage at the 12V rail (from PCI edge connector): 12V ± 8 percent.
•
Power Supply voltage at the 3.3V rail (from PCI edge connector): 13.3V ± 9 percent.
•
Relative humidity range is 20 percent to 80 percent non-condensing
•
Temperature range: 10 °C to +55 °C (with or without the RMFBU module attached)
List of non-operating conditions (while in storage or in transit) for the Intel® RAID adapter
RMSP3HD080E:
•
Relative humidity range is 5 percent to 90 percent non-condensing.
•
Temperature range: –40°C to +70°C without battery backup unit
3.6.2
Intel RAID Adapter RMSP3MD088F Consumption.
The following table describes the power consumption of the Intel® RAID adapter RSP3TD160F
under the following states:
State 1: While sitting idle at the DOS prompt or the EFI shell.
State 2: During a drive stress test; average over 20 minutes of sustained operation
Power Mode
State 1
State 2
Typical
Typical
RMFBU learn
3.3V Supply
0.23W
0.20W
+ 12 Supply
16.40W
17.48W
N/A
3.3V Auxillary Supply
0.07W
0.03W
Total Power
16.70W
17.71W
N/A
3.7
Intel RAID Adapter RMSP3WD080E
The Intel® RAID module RMSP3WD080E an entry level tri-mode RAID adapter with 8 internal ports based on
the Avago® SAS3408 SAS I/O Controller (IOC). It supports RAID levels 0, 1,10 and hybrid 5. It has an x8 PCI
Express* 3.0. PCIe interface and it supports up to 64 physical devices* and up to 32 virtual drives**. The
next figure describes the connectors for this adapter.
** Physical devices include expanders and if dual-ported back planes are being used, each drive counts twice.