![Intel RealSense ID Solution F450 Datasheet Download Page 11](http://html1.mh-extra.com/html/intel/realsense-id-solution-f450/realsense-id-solution-f450_datasheet_2072032011.webp)
Hardware Details
Rev: 001
11
2.1
Host Interconnect
The
Intel® RealSense™ ID Solution
F450 module requires external power and a serial
data link for initialization and control of the Face Authentication system. Data signals
and external power are both routed through the same host connector interface.
2.1.1
Data Interface
The
Intel® RealSense™ ID Solution
F450 supports both UART and USB2 interfaces for
the data link. The boot up interface is configured through a FW and module strap
option.
Table 2-2: Data Interface
SECTION
DATA RATE
PINS
UART
(3V Interface)
115.2kbs to 4Mbps
UART_TX (Pin 47), UART_RX (Pin 49)
USB2
480Mbs
USB2_DP (Pin 46), USB2_DN (Pin 48)
2.1.2
Power Interface
The
Intel® RealSense™ ID Solution
F450 module has a peak power of up to 3W. The
host system must ensure the power supply can satisfy this peak power based on the
chosen
Intel® RealSense™ ID Solution
F450 voltage source (VDD). If the host
module supports power gate control it is the responsibility of the host module to
ensure no conflicts between power sequencing and data link initialization occurs
during power-up and power-down cycles.
Table 2-3: Power Interface
PIN
VOLTAGE RANGE
PEAK POWER
VDD (Pin 51/52)
3.15 to 5.0V
2.1
–
3.0W
(1)(2)
GND
-
-
NOTES:
(1)
The power range is primarily dependent on illumination power set by the device.
(2)
The typical max current for a USB2 port is 450mA, USB3 port is 900mA.
The
Intel® RealSense™ ID Solution
F450 supports three device states, off, standby,
and operation. In the off state the
Intel® RealSense™ ID Solution
F450 is shutdown
and the power supply from the host is disabled. In the standby, the Intel®
RealSense™ ID Solution
F450 power supply is enabled, the SOC is in an execution
loop for manageability access or FW update, but the optical components are powered
down. In the operation state, the power supply is enabled, SOC is running FA
enrollment or authentication usage with the optical components activated.
Summary of Contents for RealSense ID Solution F450
Page 7: ...Rev 001 7 Revision History Revision Description Date 001 Initial Public Release January 2021...
Page 9: ...Overview Rev 001 9 Figure 1 2 Intel RealSense ID Solution F450 Module Host System Topology...
Page 37: ...Appendix A Interposer Reference Designs Rev 001 37 Figure 8 2 UART Interposer Reference Design...