6
NEXXUS4080AL
User’s Guide
Figure 4. Recovery Jumpers
Jumper Name
Jumper Purpose
CMOS Clear
If pins 2-3 are jumpered, the CMOS settings will be cleared on the next
reset. These pins should be jumpered on 1-2 for normal operation.
Password Clear
If pins 2-3 are jumpered, administrator and user passwords will be cleared
on the next reset. These pins should be jumpered on 1-2 for normal
operation.
BMC Force Update Mode
If pins 2-3 are jumpered, BMC Force Update Mode is enabled. These pins
should be jumpered on 1-2 for normal operation.
TP02080
3
2
Password
Reset
J1D2
J1D3
3
2
Clear
CMOS
BMC Force
Update Mode
3
2
J1D1
Disable
Enable