Align the Pin 1 indicator of processor carrier clip with one of the diagonally cut corners on the
base of the heat sink. Or (If present) look for the Pin 1 indicator on the corner of the heat sink
label.
•
Gently press down the heat sink onto the processor carrier clip until it clicks into place.
•
Ensure all four heat sink corners are securely latched to the carrier clip tabs.
2.3.2
PHM Installation
If installed, remove the plastic cover from the processor socket.
Caution:
Do not touch the socket pins. The pins inside the processor socket are extremely sensitive. A
damaged processor socket may produce unpredictable system errors.
Figure 14. Processor Socket Cover Removal
•
Remove the protective socket cover by squeezing the finger grips (see Letter “A”) and pulling
the cover up (see Letter “B”).
•
Ensure the socket is free of damage or contamination before installing the PHM.
Caution:
If debris is observed, blow it away gently. Do not remove it manually, such as with tweezers.
1.
Orient and position the PHM over the processor socket (See
Figure 15. PHM Alignment with Processor Socket Assembly
•
Align the Pin 1 indicators of the processor carrier clip and processor with the Pin 1 indicator
on the socket assembly bolster plate.
Summary of Contents for M20NTP1UR
Page 2: ...2 This page intentionally left blank...
Page 101: ...Intel Server System M20NTP1UR System Integration and Service Guide 101 1 2 3 4 5...
Page 102: ...Intel Server System M20NTP1UR System Integration and Service Guide 102 1 2 3 4 5 6 1 2 3...
Page 103: ...Intel Server System M20NTP1UR System Integration and Service Guide 103 1 2 3 4 5...
Page 112: ...Intel Server System M20NTP1UR System Integration and Service Guide 112 1 2 3 4 5 ESD 6 1 2 3...
Page 113: ...Intel Server System M20NTP1UR System Integration and Service Guide 113 1 2 3 4 5...