4.
Instructions
1) Connect the power supply
Set the Power Supply to 12V/10A.
Connect the power supply to the board (make sure that the power supply is OFF) with
two patch cables, not longer than 12 inches (30 cm). Using longer wires is possible,
provided that additional bulk is added to the board (the C45 through-hole capacitor
footprint is available for this purpose) and the input voltage is monitored at the board
level. Please use INPUT GROUND and INPUT VOLTAGE eyelet-terminated cables to
connect the power.
Please observe the correct polarity.
CAUTION:
Incorrect polarity of the power supply may cause permanent
board damage!
CAUTION:
Power supply voltage above 20V may cause permanent board
damage!
2) Connect the load
Connect the load to the OUTPUT GROUND and OUTPUT voltage with patch cables, no
longer than 12 inches (30 cm).
Please observe the correct polarity.
3) Check jumper settings
The board will arrive with one jumper on the J6 (BUS – enabling control through PMBUS),
one jumper on J14 (INT – this enables the on-board 5V power supply) and one jumper
on J15 (AUX_PVIN – this biases the 5V on board DC-DC converter). If an auxiliary 5V
power supply is needed (connected between J16 (+) and J17 (-)), J14 should be placed
across the “EXT” position while J15 can be removed.
Although “TRACK” and “SYNC” use 100 mils headers, they are NOT to be shorted by
jumpers.
4) Connect the PMBUS GUI interface dongle
The USB Dongle can be inserted only in the correct position, with pin one towards GND.
All pins must be properly inserted.
Prerequisite: the latest GUI software must be installed on a Windows PC.