Intel Desktop Board DQ43AP Technical Product Specification
58
Figure 15 shows the locations of the localized high temperature zones.
Item Description
A
Processor voltage regulator area
B Processor
C
Intel 82Q43 GMCH
D
Intel 82801JD (ICH10D)
Figure 15. Localized High Temperature Zones
Table 27 provides maximum case temperatures for the board components that are
sensitive to thermal changes. The operating temperature, current load, or operating
frequency could affect case temperatures. Maximum case temperatures are important
when considering proper airflow to cool the board.
Table 27. Thermal Considerations for Components
Component
Maximum Case Temperature
Processor
For processor case temperature, see processor datasheets and
processor specification updates
Intel 82Q43 GMCH
103
o
C (under bias)
Intel 82801JD (ICH10D)
112
o
C (under bias)