RAID Migration Instructions
R
19
RAID Migration Instructions
The Intel Application Accelerator offers the flexibility to upgrade from a single Serial ATA
(SATA) hard drive to a two drive RAID 0 or RAID 1 configuration when an additional SATA
hard drive is added to the system. This process will create a new RAID volume from an existing
disk. However, several important steps must be followed at the time the system is first configured
in order to take advantage of RAID when upgrading to a second SATA hard drive:
1. BIOS must be configured for RAID before installing Windows* XP on the single SATA hard
drive. Refer to Section 10 and 11 to properly configure the BIOS.
2. Install the Intel Application Accelerator during Windows Setup. Refer to Section 12 for
instructions on installing the driver during Windows Setup.
3. Install the Intel Application Accelerator after the operating system is installed. See Section
14.3 for where the Intel Application Accelerator can be downloaded.
To create a volume from an existing disk, complete the following steps:
Warning:
A ‘Create from Existing Disk’ operation will delete all existing data from the added disk and the
data cannot be recovered. It’s critical to backup all important data on the added disk before
proceeding. However, during the migration process, the data on the source disk is preserved.
60
User's Manual
Summary of Contents for Application Accelerator
Page 1: ...Intel Application Accelerator User s Manual Revision 2 0 June 2004 ...
Page 8: ...R This page is intentionally left blank 8 User s Manual ...
Page 10: ...Scope of This Document R This page is intentionally left blank 10 User s Manual ...
Page 12: ...RAID Background R This page is intentionally left blank 12 User s Manual ...
Page 14: ...RAID 0 Striping R This page is intentionally left blank 14 User s Manual ...
Page 16: ...RAID 1 Mirroring R This page is intentionally left blank 16 User s Manual ...
Page 18: ...Matrix RAID Two Volumes Per Array R This page is intentionally left blank 18 User s Manual ...
Page 20: ...RAID Migration Feature R This page is intentionally left blank 20 User s Manual ...
Page 23: ...Advanced Host Controller Interface Native Command Queuing R User s Manual 23 ...
Page 26: ...Intel Application Accelerator R This page is intentionally left blank 26 User s Manual ...
Page 30: ...BIOS Importance Settings R This page is intentionally left blank 30 User s Manual ...
Page 57: ...Issues During Installation R This page is intentionally left blank User s Manual 57 ...