Intel 6700PXH 64-BIT PCI HUB - MECHANICAL DESIGN Design Manual Download Page 7

R

 

 

Intel

®

 6700PXH 64-bit PCI Hub Thermal/Mechanical Design Guidelines

  

 

1 Introduction 

As the complexity of computer systems increases, so do the power dissipation requirements. Care 
must be taken to ensure that the additional power is properly dissipated. Typical methods to improve 
heat dissipation include selective use of ducting, and/or passive heatsinks. 

The goals of this document are to: 

 

Outline the thermal and Mechanical operating limits and specifications for the Intel

®

 

6700PXH 64-bit PCI Hub component. 

 

Describe a reference thermal solution that meets the specification of Intel

®

 6700PXH 64-bit 

PCI Hub component. 

Properly designed thermal solution provides adequate cooling to maintain the PXH component die 
temperatures at or below thermal specifications. This is accomplished by providing a low local-
ambient temperature, ensuring adequate local airflow, and minimizing the die to local-ambient 
thermal resistance. By maintaining the PXH component die temperature at or below the specified 
limits, a system designer can ensure the proper functionality, performance, and reliability of the 
chipset. Operation outside the functional limits can degrade system performance and may cause 
permanent changes in the operating characteristics of the component.  

The simplest and most cost effective method to improve the inherent system cooling characteristics 
is through careful chassis design and placement of fans, vents, and ducts. When additional cooling is 
required, component thermal solutions may be implemented in conjunction with system thermal 
solutions. The size of the fan or heatsink can be varied to balance size and space constraints with 
acoustic noise. 

This document addresses thermal design and specifications for the Intel

®

 6700PXH 64-bit PCI Hub 

components only. For thermal design information on other chipset components, refer to the 
respective component datasheet.  

Unless otherwise specified, the term “PXH” refers to the Intel

®

 6700PXH 64-bit PCI Hub. 

1.1 

Definition of Terms 

BGA 

Ball grid array. A package type, defined by a resin-fiber substrate, onto which a die is 
mounted, bonded and encapsulated in molding compound. The primary electrical 
interface is an array of solder balls attached to the substrate opposite the die and molding 
compound.  

BLT 

Bond line thickness.  Final settled thickness of the thermal interface material after 
installation of heatsink. 

MCH 

Memory controller hub. The chipset component that contains the processor interface, the 
memory interface, and the hub interface.  

PXH Intel

®

 6700PXH 64-bit PCI Hub. The chipset component that performs PCI bridging 

functions between the PCI Express* interface and the PCI Bus. It contains two PCI bus 
interfaces that can be independently configured to operate in PCI (33 or 66 MHz) or 
PCI-X mode 1 (66, 100, or 133 MHz), for either 32 or 64 bit PCI devices. 

Summary of Contents for 6700PXH 64-BIT PCI HUB - MECHANICAL DESIGN

Page 1: ...R Intel 6700PXH 64 bit PCI Hub Thermal Mechanical Design Guidelines August 2004 Document Number 302817 003...

Page 2: ...erves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them The Intel 6700PXH 64 bit PCI Hub chipset component...

Page 3: ...Zero Degree Angle Attach Methodology 15 6 Reference Thermal Solution 17 6 1 Operating Environment 17 6 2 Heatsink Performance 17 6 3 Mechanical Design Envelope 18 6 4 Board Level Components Keepout Di...

Page 4: ...2 Torsional Clip Heatsink Volumetric Envelope for the Intel 6700PXH 64 bit PCI Hub Chipset Component 18 6 3 Torsional Clip Heatsink Board Component Keepout 19 6 4 Retention Mechanism Component Keepou...

Page 5: ...sign Guidelines 5 Revision History Revision Number Description Date 001 Initial release Jul 2004 002 Added reference thermal solution rails to PXH package footprint drawing in Section 6 5 Aug 2004 003...

Page 6: ...Introduction R 6 Intel 6700PXH 64 bit PCI Hub Thermal Mechanical Design Guidelines...

Page 7: ...rove the inherent system cooling characteristics is through careful chassis design and placement of fans vents and ducts When additional cooling is required component thermal solutions may be implemen...

Page 8: ...following documents Intel 82801EB I O Controller Hub 5 ICH5 and Intel 82801ER I O Controller Hub 5 R ICH5R Datasheet Intel 82801EB I O Controller Hub 5 ICH5 and Intel 82801ER I O Controller Hub 5 R IC...

Page 9: ...mm 17 00 mm 0 200 in Figure 2 2 Intel 6700PXH 64 bit PCI Hub Package Dimensions Side View 0 20 C Die Substrate 0 435 0 025 mm See Note 3 Seating Plane 2 010 0 099 mm See Note 1 Decoup Cap 0 7 mm Max 2...

Page 10: ...bare die which is capable of sustaining a maximum static normal load of 15 lbf The package is NOT capable of sustaining a dynamic or static compressive load applied to any edge of the bare die These...

Page 11: ...Intel recommends that system designers plan for a heatsink when using the PXH component 3 2 Die Case Temperature Specifications To ensure proper operation and reliability of the PXH component the die...

Page 12: ...Thermal SpecificationsThermal Simulation R 12 Intel 6700PXH 64 bit PCI Hub Thermal Mechanical Design Guidelines...

Page 13: ...esigners in simulating analyzing and optimizing their thermal solutions in an integrated system level environment The models are for use with the commercially available Computational Fluid Dynamics CF...

Page 14: ...Thermal SimulationThermal Simulation R 14 Intel 6700PXH 64 bit PCI Hub Thermal Mechanical Design Guidelines...

Page 15: ...onduction through thermocouple leads or contact between the thermocouple cement and the heatsink base if a heatsink is used For maximum measurement accuracy only the 0 thermocouple attach approach is...

Page 16: ...H 64 bit PCI Hub Thermal Mechanical Design Guidelines Figure 5 1 Zero Degree Angle Attach Heatsink Modifications NOTE Not to scale Figure 5 2 Zero Degree Angle Attach Methodology Top View Cement Therm...

Page 17: ...nimum recommended airflow velocity through the cross section of the heatsink fins is 200 linear feet per minute lfm The approaching airflow temperature is assumed to be equal to the local ambient temp...

Page 18: ...Heatsink Base Die TIM FCBGA Solder Balls Heatsink Fin Heatsink Fin 31 00mm 31 00mm 14 71mm 1 86mm 3 01mm 3 00mm 6 4 Board Level Components Keepout Dimensions The locations of hole pattern and keepout...

Page 19: ...756 2x 0 943 PXH 2x 0 878 1 886 Max component Height 0 50 Component keepout area NOTE All dimensions are in inches Figure 6 4 Retention Mechanism Component Keepout Zones 0 500 0 345 0 120 0 750 0 170...

Page 20: ...re 6 6 Heatsink Rails to PXH Package Footprint 6 5 2 Extruded Heatsink Profiles The reference torsional clip heatsink uses an extruded heatsink for cooling the PXH component Figure 6 7Figure 6 7Figure...

Page 21: ...ure increases on the TIM the thermal resistance of the TIM decreases This phenomenon is due to the decrease of the bond line thickness BLT BLT is the final settled thickness of the thermal interface m...

Page 22: ...echanical loading of the component Based on the end user environment the user should define the appropriate reliability test criteria and carefully evaluate the completed assembly prior to use in high...

Page 23: ...tsink 31 0 x 31 0 x 12 2 mm C76434 001 CCI ACK Harry Lin USA 714 739 5797 hlinack aol com Monica Chih Taiwan 866 2 29952666 x131 monica_chih ccic com tw Thermal Interface Chomerics T 710 A69230 001 Ch...

Page 24: ...Thermal Solution Component Suppliers R 24 Intel 6700PXH 64 bit PCI Hub Thermal Mechanical Design Guidelines...

Page 25: ...B 1 lists the mechanical drawings included in this appendix Table B 1 Mechanical Drawing List Drawing Description Figure Number Torsional Clip Heatsink Assembly Drawing Figure B 1Figure B 1Figure B 1...

Page 26: ...Mechanical Drawings R 26 Intel 6700PXH 64 bit PCI Hub Thermal Mechanical Design Guidelines Figure B 1 Torsional Clip Heatsink Assembly Drawing...

Page 27: ...R Mechanical Drawings Intel 6700PXH 64 bit PCI Hub Thermal Mechanical Design Guidelines 27 Figure B 2 Torsional Clip Heatsink Drawing...

Page 28: ...Mechanical Drawings R 28 Intel 6700PXH 64 bit PCI Hub Thermal Mechanical Design Guidelines Figure B 3 Torsional Clip Drawing...

Reviews: