17
PRELIMINAR
Y
PRELIMINAR
Y
Sets the amount of clicks on the encoder it takes to get to full 100% of
throttle
Sets the backlight to either On (fade mode) or off (stays off)
Sets the time it takes for the deadman to stop the locomotive when no
input is received, in seconds
Sets the format the system shows speed and distance.
Sets the sensitivity of the accelerometer inside the handset. This is the
amount of time the handset has to be in free-fall before it E-stops
Sets the threshhold for the autoreverse limit. The locomotive can be
reversed, as long as it is not throttled up beyond this limit.
Sets the maximum available throttle that can be set. Limits the maximum
speed of the locomotive.
Sets the default brake pressure that is available upon system start. This is
also the setting the Emergency stop feature uses by default.
Sets the absolute maximum brake pressure the system can reach.
Sets the acceleration behavior of the locomotive (how fast or slow it accel-
erates) in percent per second . a higher value means a faster acceleration
Set the deceleration behavior of the locmotive (how fast or slow it deceler-
ates) in percent per second. a higher value means a faster stop
Sets the wheel diameter of your locomotive. This is needed for correct
speed calculation via speed-sensor input. If you use the sensor on a fly
-
wheel (before a reduction occours) you need to divide your wheel diameter
by that reduction and set it accordingly. (5” wheel 1:2 reduction = 2.5”)
reserved setting. no function currently
Sets the amount of batteries in the system. This is needed to correctly
calculate voltages and battery levels.
Sets the gain for the sound module’s rung calculation. at high loads the
engine will sound more tasked.
Can be set either to fuse input (fuse detection) or Temperature sensor.
(This feature is currently only implemented but not enabled)
Sets the global brightness of the front lights. Dim will be calculated from
this too. (about half)
Sets the global brightness of the rear lights. Dim will be calculated from
this too (about half)
Determines how long the ditchlights keep flashing when triggered
Selects the type of lighting system and system voltage.
Incandescent 24 or 36V
1 LED per channel @ 24 or 36 v
2 LED per channel @ 24 or 36V
(continued on page 18)
Handset setup:
Throttle Resolution
(range 8-100)
Backlight on/off
(range on/off)
Deadman Timeout
(0-30 seconds)
Speed Format
(mph/smph/kph/skph)
Drop sensor
(5-100ms)
Auto-reverse Limit
(1-50%)
Locomotive setup:
Maximum Speed
(10-100%)
Default Brake Prsr.
(0-50psi)
Maximum Brake Prsr.
(10-80psi)
Acceleration
(1-50%/s)
Deceleration
(1-50%/s)
Wheel diameter
(1.000 to 8.000 inch)
Electric or Gasoline
Battery Count
(2-6 bat)
Load Current Gain
(1-20)
Sensor input 1 to 4
Front Light Level
(0-15)
Rear Light Level
(0-15)
Ditchlight time
Lighting System
Description of functions:
Summary of Contents for LOCOn TROLLER LT 150 A
Page 1: ...LOCOnTROLLER Model LT 150 A User Manual...
Page 2: ......
Page 21: ...21 P R E L I M I N A R Y 7a Front panel Pinout...
Page 22: ...22 P R E L I M I N A R Y...
Page 23: ...23 P R E L I M I N A R Y...
Page 32: ...32 P R E L I M I N A R Y 9 Wiring Diagram provided Externally...
Page 33: ...33 P R E L I M I N A R Y...
Page 34: ...34 P R E L I M I N A R Y Notes...
Page 35: ...Notes...
Page 36: ...2016 Integral Circuits LLC...