background image

 

SW-PRO 800/1100/1600/2200VA 

 

 

www.xmart-ups.com

             

                                        

VER. 2210.03-IM

                                                                        

3

 

3.

 

PRODUCT DESCRIPTION 

 

SW-PRO  800/1100/1600/2000  series  offers  4  different  UPS  models,  all  of  them  interactive  type  with  internal  automatic 
voltage regulation and sinewave output in battery mode.  
  

 

 

4.

 

INSTALLATION 

 

TO MAKE SURE UPS WILL BE ABLE TO OFFER YOU EXPECTED BACKUP,  FIRST TIME PLUG 

UPS TO AC SOURCE DURING 4 TO 6 HOURS TO ALLOW RECHARGING INTERNAL BATTERIES. 

 

 

This UPS leaves factory with battery fully charged, however during transportation and storage it may lose a non 

determined part of its charge; therefore, we recommend plugging it to Power Line for 6 hours before using the UPS. 

 

Install this unit in any protected environment with a dust free air flow.  Also, corrosive vapours and conductive 

contaminants  must  be  avoided.  Do  not  use  UPS  outdoors  or  where  either  temperature  or  humidity  exceeds  tech 

specs. Install UPS at least 10 inches away from your monitor to avoid magnetic interference. 

 

Connect phone or LAN cable to RJ11/45 Jack Identified as “IN” and your Router or PC RJ45 port to RJ

-11/45 

Jack Identified as “OUT”. Plug UPS to a power outlet with a proper grounding. Connect your equipments to UPS 

power outlets. 

 

NEVER connect equipments  with  power consumption  higher than  Power Capacity  of  this  UPS,  such  as  Laser 

Printers or copiers.  

 

This unit MUST NOT be installed into closed boxes/cabinets that avoid fresh air access. During normal operation, 

this unit needs  fresh  air to  flow through ventilation  system  (Vents) to  cool  power circuits.  Installing  this  unit in  a 

closed  box/cabinet  makes  inner  air  to  be  recycled  without  refreshing,  increasing  inside  temperature,  exceeding 

operation max. temperature, and causing permanent damage to the UPS. 

 

THIS  KIND  OF  UPS  IS  NOT  COMPATIBLE  WITH  GENERATOR  POWER  PLANTS.  DO  NOT 

CONNECT TO ELECTRICAL SUORCE SUPPLIED BY  GENERATOR POWER PLANTS SINCE UPS 

WILL NOT WORK PROPERLY. 

 

Summary of Contents for Xmart SW-PRO 800

Page 1: ...istributed totally or partially without written approval of XMART XMART can introduce modifications in their products or manuals without further notice XMART is not responsible of mistakes or missing...

Page 2: ...edical equipments life support equipments microwave ovens vacuum cleaners refrigerators or any other appliance to this UPS WARNING UPS must be checked repaired and maintained by qualified personnel on...

Page 3: ...ure or humidity exceeds tech specs Install UPS at least 10 inches away from your monitor to avoid magnetic interference Connect phone or LAN cable to RJ11 45 Jack Identified as IN and your Router or P...

Page 4: ...ction allows you to power up your UPS and your equipments even during power loss thus your UPS acts like a small power generator 6 SOFTWARE Our software offers great features to communicate your PC an...

Page 5: ...at least 6 hours 9 QUALITY PERFORMANCE SAFETY SAFETY LOW VOLTAGE DIRECTIVE 2014 35 EU UPS Part 1 1 General Safety UPS in accessible areas IEC EN 62040 1 ELECTROMAGNETIC COMPATIBILITY EMC DIRECTIVE 201...

Page 6: ...turned product is free of failure or it is out of warranty because any of the reasons described in this warranty 6 If product is out of warranty a reparation proposal will be sent to the user for his...

Page 7: ...et Weight kgs UPS Overload Alto consumo en salida 2 beeps s Battery Fault Falla Bater as 1 beep 2s UPS Fault falla UPS Continuos Beep BEEP ALARMS Battery Mode Modo Bater a 1 beep 10s Battery Low Level...