14.04-8

OUTSTATION LAYOUT.

OUTSTATION LAYOUT.

2-Wire RS485 Serial Connections.

4-Wire RS422 Serial Connections.

4
6
3
9
5

Shimaden FP21

with RS422 option

4
6
3
9
5

Shimaden SR25/253

with RS422 option

25
24
23
22
21

Shimaden SR53/54

with RS422 option

5
4
3
2
1

Shimaden SR73A/74A

with RS422 option

To other INTECH MICRO Remote

Stations & Shimaden Controllers etc.

End of Data

Hi-way

Junction Box.

TWISTED

P

AIR

IN-2000-AI

Remote Station.

2100-AO

Remote Station.

IN-2000-DI

Remote Station.

2100-A

4

Remote Station.

21

20

23

22

36

35

38

37

70

71

72

73

74

2100-D

Remote Station.

70

71

72

73

74

IN-2000-DO

Remote Station.

26

25

28

27

21
22

1

Shimaden SD20

with RS485 option.

23
22

21

Shimaden SR53/54
with RS485 option.

3
2

1

Shimaden SR73A/74A

with RS485 option.

To other INTECH MICRO

Remote Stations &

Shimaden Controllers etc.

Resistor = 1k

.

2100-A16

Remote Station.

2100-A

4

Remote Station.

2100-AO

Remote Station.

70

71

74

70

71

74

70

71

74

Notes:
(i) RS485 can only be used with software release Ver. 4.02 onwards.
(ii) RS485 Data Hi-way is not compatible with RS422 Data Hi-way devices

such as IN-2000-AI, IN-2000-AO, IN-2000-DI, IN-2000-DO, FP21,
SR25, etc. Use a 2100-4S to interface an RS485 Data Hi-way to an
existing RS422 Data Hi-way

RS232:

2100-IS convertor is not required to connect the 2100-232
directly to a PC. Use the RS232 kit to connect the 2100-232
directly to a PC. The PC requires one RS232 port per 2100.

RS485:

If the outstation is using RS485, it cannot be connected to the same
data hi-way as an outstations using RS422. In the ‘programming’
box, set the ‘TX  delay’ box to 20. Set the Dip switches on the
2100-IS and the jumpers on the 2100 for RS485 operation.

24
23
21
22
1

Shimaden SD20

with RS422 option

3
9

5

Shimaden SR253

with RS485 option.

2100-A

16

Remote Station.

70

71

72

73

74

IMPORTANT:
(i) All cables must be

screened.

(ii) All screens must

be connected
together.

(iii) The screen must

not be earthed at
any point.

IMPORTANT:
(i) All cables must be

screened.

(ii) All screens must

be connected
together.

(iii) The screen must

not be earthed at
any point.

2100-D

Remote Station.

70

71

74

70

71

72

73

74

DO NOT GUESS TX OR RX CONNECTIONS. FOLLOW THE TERMINAL NUMBERS IN THE SERIAL CONNECTION DIAGRAMS EXACTLY.

 

-

 +

SG

Shimaden SR80 Series

with RS485 option.

Shimaden SR90 Series

with RS485 option.

SR82

18

17

16

SR83

25

24

23

SR84

22

21

1

 

-

 +

SG

SR91

12

11

1

SR92,93,94

3

2

1

Resistor = 1k

.

TWISTED

P

AIR

TWISTED

P

AIR

TWISTED

P

AIR

TWISTED

P

AIR

TWISTED

P

AIR

End of Data

Hi-way

Junction Box.

74           71  70

Terminal Numbers

COM

                TX+   TX-

RS485 DATA HI-WAY.

CABLE POLARITY

MUST BE OBSERVED

RS422 DATA HI-WAY.

CABLE POLARITY

MUST BE OBSERVED

RS485 DATA HI-WAY.

CABLE POLARITY

MUST BE OBSERVED

RS422 DATA HI-WAY.

CABLE POLARITY

MUST BE OBSERVED

74 73 72 71 70

Terminal Numbers

com 

  RX+   RX-   TX+    TX-

74           71  70

COM

                TX+   TX-

74 73 72 71 70

com 

  RX+   RX-   TX+    TX-

2100-NET

10/100 Ethernet to
RS422/485 Converter.

COMPUTER

PLC

2100-IS/NS

RS232 to RS422/485

Converter/Isolator.

2100-NET

10/100 Ethernet to
RS422/485 Converter.

RS232

ETHERNET

COMPUTER

PLC

2100-IS/NS

RS232 to RS422/485

Converter/Isolator.

The 2100-IS and 2100-NET are

designed to connect to seperate data

hi-ways and connect to the same

SCADA PC as per the diagram.

RS232

ETHERNET

The 2100-IS and 2100-NET are

designed to connect to seperate data

hi-ways and connect to the same

SCADA PC as per the diagram.

70
71
72
73
74

2100-4S RS422

to RS485 Converter

70
71

74

RS485

Only one converter to be

connected to any one data hiway.

OR

Only one converter to be

connected to any one data hiway.

OR

Summary of Contents for 2100-D

Page 1: ...INTECH Micro 2100 D REV 1 1 Installation Guide 14 04 1 TECHNOLOGY QUALITY A W A RD ISO9001 E G ISTE R RE D M ANU A T U R E R C F Z985...

Page 2: ...xample Diagram for Digital Outputs Page 7 Connection Example Diagram for Digital Inputs Page 7 Section D Comms Connection Diagrams and Software Settings RS485 Serial Connection Page 8 RS422 Serial Con...

Page 3: ...uts RS485 COMMS 85 264Vac dc Power Supply 2100 D C PS Note The 2100 D is factory set to RS485 The 2100 D X is field selectable for RS422 or RS485 and H or M power supply Ordering Examples 1 2100 D 422...

Page 4: ...for 1 min Input Output Isolation Test Voltages Between Inputs 1000Vdc for 1min Comms to Inputs 1000Vdc for 1min Relay Outputs to All Other Terminals 3000Vac 50Hz for 1min Between Relay Outputs 1500Vac...

Page 5: ...RELAY OUT DIGITAL IN COMMS POWER Digital Input 3 Digital Input 4 Digital Input 5 Digital Input 6 Digital Input 7 Digital Input 8 Digital Input 9 Digital Input 10 Digital Input 11 Digital Input 12 TXE...

Page 6: ...t l a e h n o i t a t S s e t a c i d n i g n i h s a l f l a u n i t n o C t a e b t r a e H 2 1 1 t u p t u O d e z i g r e n e s i y a l e r t u p t u o e v i t c e p s e r r i e h t n e h w s e t...

Page 7: ...nction does not detect microprocessor failure When used for this function the relay cannot be used for any other function Note 5 LED indication on each output when each relay is energized 14 04 7 2100...

Page 8: ...ation 24 23 21 22 1 Shimaden SD20 with RS422 option 3 9 5 Shimaden SR253 with RS485 option 2100 A16 Remote Station 70 71 72 73 74 IMPORTANT i All cables must be screened ii All screens must be connect...

Page 9: ...TX TX RX RX 82 81 80 74 73 72 71 70 49 48 47 2100 RS232 Kit Omron RS232 Kit for Omron PLC Includes 2m cable 9 pin D type Connector Installation Plug one end of the RS232 Comms cable into the RS232 RJ1...

Page 10: ...p 3 Move to the required station number using next or prev buttons 4 Select Program Setup The serial number of the 2100 D will be recalled automatically The software recalls the settings from the outs...

Page 11: ...ng is completed ie terminals 82 81 and 80 For Non Hazardous Voltage power supplies not exceeding 42 4Vpeak or 60Vdc terminals 81 and 80 may be linked together instead of connecting an earth RS422 485...

Page 12: ...r supplies with ungrounded outputs 4 Lightning arresters should be used on inputs and outputs when there is a danger from this source 5 Refer to diagrams for connection details Commissioning 1 Check t...

Reviews: