Machine is on, yet no material
comes out of hose.
Slide gate is closed.
Open slide gate.
Insulation blockage in hose.
Turn system off, remove hose
and clear blockage.
Air pocket in hopper is
preventing insulation from
feeding into agitators.
Disconnect electrical power.
Redistribute insulation material
inside hopper.
Airlock seal is worn.
Inspect airlock seals for cuts
and wear. Have a qualified
technician replace airlock seals.
Airlock has an obstruction
preventing insulation from
exiting.
Disconnect electrical power,
remove obstruction.
Insulation exiting hose is
dribbling out.
Heavy insulation material.
Push slide gate in 1-2 holes.
Kink in hose.
Straighten hose.
Airlock seal is worn.
Inspect airlock seals for cuts
and wear. Have a qualified
technician replace airlock seals.
Circuit breakers need resetting
often.
Low voltage or low amperage.
System requires 115V / 15amp
separate
circuit for agitator and
blower.
Extension cord gauge is too
small.
Use a 12/3 heavy duty (i.e.
SJ300V) extension cord when
length is 100’ or less. Use a
10/3 heavy duty extension cord
when length is over 100’.
You are using a generator with
high voltage oscillations.
Purchase a generator with low
harmonic distortion.