View and edit the
marked parameters if necessary
Loop
4 Traffic generator (GigE)
ARGUS
21
Settings select and edit.
Quit the menu without saving
the changes.
Setting
Explanation
Test parameters:
Traffic generator:
Bandwidth
Determine the bandwidth that the ARGUS will generate with the Traffic
generator.
Range: 1 kbit/s to 1000000 kbit/s.
Default setting:
10.000 kbit/s
Mode
The following modes are for limiting the Traffic generation: Time,
Frames and Endless.
Default setting:
Endless
Duration
Determines the duration of the test. Range: 00:00:01 to 99:99:99
Default setting:
00:00:01
Number of
frames
Determines the number of frames which are generated for the test.
Range: 1 to 999999999
Default setting:
50.000
Frame size
Determines the frame size which is used.
Range: 64 Bytes to 1518 Bytes.
Default setting:
1518 Bytes
Own IP
address
Enter the own IP address. Range: 0.0.0.0. to 255.255.255.255
Default setting:
0.0.0.0
Own UDP
port
Enter the own UDP port.
Range: Port number 0 to 65535
Default setting:
Port number 7