Sensor Range
The sensing range of the tap is pre-set and should not require adjustment.
If needed, users can customise it between 5 and 25 cm ap proximately.
Remove the top cover of the tap and disconnect the battery box.
Wait for 30 seconds then reconnect the battery box to restore power to sensor.
Immediately place a hand in front of the sensor at a maximum distance of 5 cm with red light
flashing (if it stops flashing remove the power supply again and repeat the whole procedure).
Wait until red light is on constantly and then move your hand to the desired distance.
Wait for the light to turn off before removing your hand to set new range, at this point the new
range is set.
Reducing the Maximum Temperature
If the hot water supply is at a high temperatures, to avoid scalds to the user or for energy saving
reasons it is possible to limit the temperature of the water sup plied to the user.
It is recommended that the mixed water temperature is set using a digital thermometer at the
outlet from the tap.
Turn the mixing lever until the desired temperature has been reached.
Once the desired temperature has been reached, remove the lever and the lock ing ring nut and
reassemble the lever at the new maximum temperature, taking care not to move the position
of the tap, make sure to position the ring fully oriented towards the new setting.
ATTENTION: this procedure mechanically locks the mixing between hot and cold water, but
does not regulate the supply temperature: therefore it does not provide any protection to the
user if the cold water supply is turned off to the tap.
This procedure does not replace the requirement for a thermostatic mixing valve (TMV).
Constant Temperature
The infra red temperature adjustable tap can be
converted to constant temperature operation if
required.
The adjustable temperature lever locates on the
hexagon of the thermostatic cartridge and therefore
can adjust the temperature.
The constant temperature collar has a circular
interior which locates on the corners of the hexagon
and therefore can only rotate on the cartridge.
To convert the tap remove the indice and the retaining
screw.
It is recommended that the mixed water temperature is
set using a digital thermometer at the outlet from the tap.
Turn the mixing lever until the desired temperature has been reached.
Remove the adjustable temperature lever and replace with the constant temperature collar.
Secure with the retaining screw and refit the indice.
Indice
Retaining
screw
Adjustable
temperature
lever
Constant
temperature
collar