background image

© Intatec Ltd 2022

4

Technical Specification Continued

 

Operating Principle

  Presence detection

 

   By placing your hands near the sensor, the tap is turn on and water flows from the spout, this  

  stops as soon as the hands are removed.

 On/off

   By moving your hands close to the sensor, the tap will start dispensing wa ter.
   In order to stop it, move your hands close to the sensor a second time, otherwise it will stop  

  automatically after one minute. 

Installation

  1  A service valve and check valve should be installed in the water supply pipes to the valve  

    should maintenance be required in the future.
  2  Turn off the water supply using the service valve (not supplied).
   3  Screw the two threaded rods and flexible hoses into the base of the tap.
  4  Install the tap to the basin using the sealing and metal horse shoe washers and the two    

    retaining nuts.
  5  The solenoid valve is located inside the tap and does not require fitting.
  6  Connect the two flexible hoses to the hot and cold supplies ensuring that the two filter sealing  

    washers are used.

Max. inlet pressure - static

8 bar

Min. operating pressure - dynamic

1 bar

Max. inlet temperature

70˚C

Maximum basin thickness

26mm

24 hour automatic Anti-Stagnation hygienic flushing cycle

Automatic calibration of the sensor field

Automatically shuts off water flow after 60 seconds if the 

sensor is covered

Inlet

½

” BSP - female flexible hose

Outlet

Flow straightener

Battery powered

Battery

CRP2 lithium

Output

6V DC

Protection

IP67

Summary of Contents for IR180CP

Page 1: ...document we have endeavoured to make the information as accurate as possible We cannot accept any responsibility should it be found that in any respect the information is inaccurate or incomplete or...

Page 2: ...h the contents list Ensure all parts are present before discarding any packaging If any parts are missing do not attempt to install your Inta electronic tap until the missing parts have been obtained...

Page 3: ...ail 2 off Steel Horse Shoe Washer 1 off Rubber Horse Shoe Washer 1 off Threaded Rod 2 off Retaining Nut 2 off Battery Box 1 off Rubber Seal for Base of Tap 1 off Seal Washer with Filter 2 off Cap scre...

Page 4: ...Intatec Ltd 2022 3 Dimensions Product Codes A B C D E E IR180CP 60 138 200 108 118 G F A E B C D...

Page 5: ...service valve not supplied 3 Screw the two threaded rods and flexible hoses into the base of the tap 4 Install the tap to the basin using the sealing and metal horse shoe washers and the two retainin...

Page 6: ...tery into the battery box 4 Position the battery box into the top of the tap and connect the power cable by pushing the two connectors together 5 The LED under the sensor window will start flashing wh...

Page 7: ...ing ring nut and reassemble the lever at the new maximum temperature taking care not to move the position of the tap make sure to position the ring fully oriented towards the new setting ATTENTION thi...

Page 8: ...filter which must be kept clean in order to ensure a suitable water flow CAUTION turn off the water supply using the service valve before unscrewing the joint to remove the filter gasket for cleaning...

Page 9: ...an the filter Blocked solenoid valve Assistance required The water flows for 1 minute without an object in front of the sensor Dirty sensor Clean the sensor window Light reflections on the sensor Remo...

Page 10: ...Intatec Ltd 2022 Notes 9...

Page 11: ...Intatec Ltd 2022 Notes 10...

Page 12: ...T18 0PF Tel 01889 272 180 Fax 01889 272 181 email sales intatec co uk web www intatec co uk E O E Intatec Ltd 2022 17 06 22 Please leave this Manual for the User To activate your product warranty plea...