© Intatec Ltd 2022
4
Technical Specification Continued
Operating Principle
Presence detection
By placing your hands near the sensor, the tap is turn on and water flows from the spout, this
stops as soon as the hands are removed.
On/off
By moving your hands close to the sensor, the tap will start dispensing wa ter.
In order to stop it, move your hands close to the sensor a second time, otherwise it will stop
automatically after one minute.
Installation
1 A service valve and check valve should be installed in the water supply pipes to the valve
should maintenance be required in the future.
2 Turn off the water supply using the service valve (not supplied).
3 Screw the two threaded rods and flexible hoses into the base of the tap.
4 Install the tap to the basin using the sealing and metal horse shoe washers and the two
retaining nuts.
5 The solenoid valve is located inside the tap and does not require fitting.
6 Connect the two flexible hoses to the hot and cold supplies ensuring that the two filter sealing
washers are used.
Max. inlet pressure - static
8 bar
Min. operating pressure - dynamic
1 bar
Max. inlet temperature
70˚C
Maximum basin thickness
26mm
24 hour automatic Anti-Stagnation hygienic flushing cycle
Automatic calibration of the sensor field
Automatically shuts off water flow after 60 seconds if the
sensor is covered
Inlet
½
” BSP - female flexible hose
Outlet
Flow straightener
Battery powered
Battery
CRP2 lithium
Output
6V DC
Protection
IP67
Summary of Contents for IR180CP