Inta IR180CP.1 Installation And Maintenance Instructions Manual Download Page 6

© Intatec Ltd 2015

5

Activating

   1   Check that the sensor windows is cleaned and remove any potential objects.
   2   Open the isolation valves on the water supplies.
   3   Fit the batteries inside the box/power supply unit, connect cable from the power supply unit 

        (3) to the cable (8) from the tap.

   4   The LED in the sensor window flashes: when it stops flashing the taps is ready for use.

Setting the Detecting Distance

    The detecting distance of the sensor is set at 12 cm but can be reset by the user from a 
    minimum of 5cm  to a maximum of 25 cm (approximately).

   1   Remove the battery from the box or turn off the power at the socket.
   2   Wait 30 seconds and reconnect the power supply.
   3   When the red LED flashes (if it switches off, it is necessary to remove the battery from the 

        box and repeat the operation), put one hand immediately in front of the sensor (at a 
        distance of max. 5cm.

   4   When the red LED lights up permanently, move your hand to the desired distance.
   5   Wait for the LED to switching off before removing your hand, at this point the new distance 

        is recorded. This new setting will be stored in case of battery replacement (or lacking of 
        electricity).

Safety Device 

   To prevent flooding of the premises following an act of vandalism or misuse (an object left in 
   front of the sensor or a dirty sensor), the tap has a safety device that shuts off the water flow 
   after about one minute. 
   Once the object has been removed (or the sensor has been cleaned), the tap starts working 
   again. Taps with a power supply unit have an anti black-out function which ensures the water 
   flow stop if the electricity supply fails and prevent it starting again until the electricity supply 
   has been restored.

Maintenance

Cleaning

    In order to keep the tap operating efficiently and maintain its appearance it is necessary to 
    periodically carry out a number of simple maintenance operations including:
    The high quality chrome finish and the darkened plastic window which protects the sensor, 
    must be kept clean to maintain correct operation, both surfaces should be treated with care.
    An occasional wipe with a mild washing-up liquid on a soft damp cloth followed by a 
    thorough rinse and wipe dry with a soft clean cloth is all that is required.
    

Do not use an abrasive or chemical household cleaner as this may cause 

   damage to the surface.

Summary of Contents for IR180CP.1

Page 1: ...urate as possible We cannot accept any responsibility should it be found that in any respect the information is inaccurate or incomplete or becomes so as a result of further developments or otherwise Intatec Ltd Airfield Industrial Estate Hixon Staffordshire ST18 0PF Tel 01889 272 180 Fax 01889 272 181 email sales intatec co uk web www intatec co uk Intatec Ltd 2015 ...

Page 2: ...8 472 791 Products Infra Red Basin Tap IR180CP 1 Check Content Before commencing remove all components from packaging and check each component with the contents list Ensure all parts are present before discarding any packaging If any parts are missing do not attempt to install your Inta shower valve until the missing parts have been obtained Technical Data Operating water pressure range 1 to 8 bar...

Page 3: ... Intatec Ltd 2015 2 Dimensions 108 56 G 119 137 60 40 5 39 70 ...

Page 4: ...3 Item Qty Component Item Qty Component 1 1 Tap 5 2 Stainless steel flexible hose 2 1 Fixing kit 6 2 Inlet nut 3 1 Battery box 7 2 Sealing washer 4 2 Wall plug and fixing screw 8 1 Power cable Components 2 5 7 6 8 3 4 1 ...

Page 5: ... Flush the water supply pipes thoroughly prior to installation Do not allow debris PTFE tape or any metal particles to enter the tap Turn off the water supply Important All plumbing to be installed in accordance with applicable codes and regulations Installation FAILURE TO OBSERVE THE INSTALLATION INSTRUCTIONS WILL INVALIDATE THE PRODUCT WARRANTY CONDITION 1 Screw the flexible hoses 5 into the inl...

Page 6: ...d This new setting will be stored in case of battery replacement or lacking of electricity Safety Device To prevent flooding of the premises following an act of vandalism or misuse an object left in front of the sensor or a dirty sensor the tap has a safety device that shuts off the water flow after about one minute Once the object has been removed or the sensor has been cleaned the tap starts wor...

Page 7: ...queries should further assistance be required our Technical Department can be contacted directly on 01889 272199 Fault Cause Solution No water flow The isolation valves are closed Open the isolation valves Exhausted battery LED flashes Replace the battery Electrical problem Check the voltage Disconnect and reconnect the battery where applicable Check the connections and the cable s integrity Damag...

Page 8: ... at its option to repair or replace any faults caused by defective material or manufacturing that may arise see Intatec Warranty The warranty does not cover dame caused by Abnormal or improper use Incorrect installation or water system problems Normal wear or negligence in maintenance and in use Acts of vandalism Contact with abrasives corrosive chemicals or unsuitable cleaning agents or instrumen...