Basics 

 

INSYS Modem 336 LL  

i-modul Modem 336 LL 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

Aug-06

 

1

 

Basics 

Leased line modems are used when a permanent connection between two data termi-
nals is required. 
For these connections no regular switched line is used, but a dedicated (leased) line. This 
can either be a line leased from Telekom, or just an unused pair e.g. on the premises. 
Leased line modems establish a connection via such a two wire line immediately after 
being switched on. 
Leased lines are sometimes “serviced” which means they don’t represent a direct two 
wire connection. The end terminals are supplied using a power supply unit. 
The INSYS Modem 366 LL / i-modul 336 LL supports both variants. They operate polarity-
independent which means that a1 and b1 are interchangeable. 

The two wire connection is the most used connection type. 

Unserviced line 

 

 
 
 
 

Serviced line 

 

i-modul 336 LL / 
INSYS Modem 336 LL 

Originate 

i-modul 336 LL / 
INSYS Modem 336 LL 

Answer 

LA 
LB 

LA 
LB 

LA 
 
 
LB 

i-modul 336 LL / 
INSYS Modem 336 LL 

Originate 

i-modul 336 LL / 
INSYS Modem 336 LL 

Answer 

LA 
 
 
LB 

Summary of Contents for i-modul 336 LL

Page 1: ...Add On Manual INSYS Modem 336 LL i modul Modem 336 LL Modem for LeasedLine operation Aug 06...

Page 2: ...information and their consequences Suggestions for improvements and comments are gladly accepted Trademarks The use of a trademark not shown below is not an indication that it is freely available for...

Page 3: ...3 PING MODE AS CONNECTION SAFEGUARD 7 2 4 STATUS TRANSMISSION OF THE DIGITAL INPUTS 8 2 5 REMOTE CONFIGURATION 8 3 DIAGNOSIS AND TESTING OF THE PATH 9 3 1 LINE OPTIMIZATION 9 3 2 ERROR SOURCES 9 3 3 D...

Page 4: ...tely after being switched on Leased lines are sometimes serviced which means they don t represent a direct two wire connection The end terminals are supplied using a power supply unit The INSYS Modem...

Page 5: ...re configured devices Originate or Answer for two wire operation The difference lies in the factory settings for the S registry values ATS11 und ATS7 Originate ATS11 3 ATS7 50 Answer ATS11 1 ATS7 30 N...

Page 6: ...uested speed must be entered with the AT command AT S n W the data format with the AT command AT U n W and then saved Dur ing the connection state the INSYS Modems 336 LL can no longer be addressed vi...

Page 7: ...ower value 2 3 PING Mode as Connection Safeguard The leased line modems have an additional connection safeguard built in which pre vents a modem connection to hang up This connection safeguard sends a...

Page 8: ...ittable frequency is at ap proximately 0 5 Hz i e the transmission may only be used for slowly changing status lines 2 5 Remote configuration If connection safeguard is activated see Chap 1 3 this may...

Page 9: ...mote terminals were set to different connection protocols V xx to be set with AT MS n The two remote terminals are fixated on different error correction proto cols None MNP V 42 a1 b1 and a2 b2 have n...

Page 10: ...k size AT A If necessary the error correction may be completely switched off using the com mand AT N0 Without error correction however transfer errors on the line are possible which means that the dat...

Page 11: ...Receiving sensitivity Approx 40dBm Device terminator Approx 600 Bridgeable distance Up to approx 15 km possible line interference dependent Connection standards V 34 V 34 V 32bis V 32 V 22 V 22bis V 2...

Page 12: ...hout error correction possible Switch to initialization by briefly pressing the RESET key All switching operation settings may be used but not all settings are suitable for LL Setting of Originate Ans...

Page 13: ...INSYS Modem 336 LL i modul Modem 336 LL Declaration of Conformity Aug 06 13 6 Declaration of Conformity...

Page 14: ......

Reviews: