Quick-Start Guide                                                           

 

         INSTEON Energy Display 

 
 

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

*Setup Modes will automatically time out after 4 minutes.  
**Temperature Calibration Mode will automatically time out after 1 minute.  
 
 

Setup Modes 

 

NOTE: Circled text indicates blinking text on the Energy Display screen.  

To enter Setup Mode, press & hold the Mode button for 3 seconds.  
To exit Setup Mode: 

 

Tap the Refresh button to accept the current value 

 

Wait for Energy Display to time out and automatically accept the current value (~1 minute) 

 

Tap the Mode button to accept the current value and move to the next Setup Mode  

Once Energy Display exits a setup mode, it will return the screen to Display Mode.  

 
Cost Mode 

Range is 0.1 to 999 cents/kWhr ($9.99/kWhr). Once the counter reaches 99.9¢, it will reset to 100¢. The default is 10.0¢. 

 

Button Action 

Mode 

Tap to cycle to the next setting mode (Temperature Format) 
Tap to increase the cost by 0.1¢ until cost exceeds 99.9¢. If cost is 100¢ or greater, 
cost increases by 1¢. 

Up 

Press & hold to continuously increase cost 
Tap to decrease the cost by 0.1¢ if cost is between 0.1¢ and 99.9¢. If cost is 100¢ or 
greater, decreases by 1¢. 

Down 

Press & hold to continuously decrease cost 

OK 

Tap to accept current Cost setting and exit Setup Mode 

Set 
button 

N/A 

 

 

Temperature Format Mode 

Range is 0 to 199 degrees. The default is Fahrenheit. 

Button Action 

Mode 

Tap to cycle to the next setting mode (Display Mode) 

Up 
Down 

Tap to toggle the temperature display between Celsius and Fahrenheit 

OK 

Tap to accept current Temperature Format setting and exit Setup Mode 

Set 
button 

N/A 

 

Linking Energy Display to an INSTEON Meter Device 

1)  Make sure the meter device is properly installed with the appliance you wish to monitor  
2)  Tap the 1/2/3 button until the desired meter position is blinking (Meter 1, 2, or 3)  
3)  Set Energy Display to Linking Mode* by pressing & holding the Refresh button until it beeps (3 seconds)  

The Energy Display Status LED should begin blinking green 

 

4)  On the meter device, press & hold the Set button for 3 seconds  

Energy Display should beep and its Status LED should stop blinking and turn off 

 

5)  Confirm that Linking was successful by checking the Energy Display screen  

The Energy Display screen should display information for the meter device you just Linked to  

Complete Instructions, Troubleshooting, and Tech Support 

Owner’s Manual:

 

www.smarthome.com/manuals/2448A2.pdf

  

Call: INSTEON Gold Support Line at 800-762-7845     

Calibrating the Temperature

 

1)  Set Energy Display to Temperature Calibration Mode** by pressing & holding the Mode and Refresh buttons simultaneously 

until the temperature setting begins blinking (3 seconds)  

2)  Use the Restart and 1/2/3 buttons to set the local temperature (based on a thermostat or other device) 

 

Tapping the Restart button will increase the temperature by one degree 

 

Tapping the 1/2/3 button will decrease the temperature by one degree  

3)  When you reach the correct temperature, tap the Refresh button to accept the local temperature 

The temperature setting should no longer be blinking  