Tips for Using Power Line Modem
• Do not plug Power Line Modem into a power strip or AC line filter.
• Some computers and their accessories can absorb Power Line Carrier (PLC) signals off the power lines.
Since Power Line Modem will be so close to the computer,
the power strip for the computer should be
filtered.
Use Smarthome’s FilterLinc
TM
#1626 on the computer’s power strip to keep the Power Line
Modem’s signals from getting absorbed by the computer equipment.
• Don't plug other PLC transmitters into the same outlet as Power Line Modem. Every PLC transmitter will
absorb the other transmitter's PLC signals when they are not transmitting. In some cases, up to half the
signal can be lost due to nearby transmitters.
• If the computer's serial port is shared with another hardware device (scanner, PDA, etc.) be sure to turn off
that device's program on the PC. If left running, the home automation software will not be able to
communicate to the Power Line Modem.
• To reset the Power Line Modem to its original factory settings, unplug it from the wall outlet and wait 10 seconds. Press and hold
its SET button, plug it back in, continue holding the SET button for 3 seconds and release. After several seconds, the Status LED
will turn on, indicating a reset is complete.
#1626 FilterLinc
TM
Plug-In Filter
rev. 02-05-2009
S
Sm
ma
arrttL
La
ab
bs
s L
Liim
miitte
ed
d W
Wa
arrrra
an
nttyy
SmartLabs warrants to the original consumer of this product that, for a period of two years from the date of purchase, this product will be free from defects in material and workmanship and will
perform in substantial conformity to the description of the product in the owner's manual. This warranty shall not apply to defects or errors caused by misuse or neglect.
IIN
NS
ST
TE
EO
ON
N a
an
nd
d T
Th
he
e IIN
NS
ST
TE
EO
ON
N C
CO
OM
MP
PA
AT
TIIB
BL
LE
E llo
og
go
o a
arre
e ttrra
ad
de
em
ma
arrk
ks
s o
off S
Sm
ma
arrttL
La
ab
bs
s,, IIn
nc
c.. U
U.. S
S.. P
Pa
attn
ntt N
No
o.. 7
7,,3
34
45
5,,9
99
98
8 IIn
ntte
errn
na
attiio
on
na
all p
pa
atte
en
ntts
s p
pe
en
nd
diin
ng
g ©
© C
Co
op
pyyrriig
gh
htt 2
20
00
09
9 S
Sm
ma
arrttL
La
ab
bs
s,, 1
16
65
54
42
2 M
Miilllliik
ka
an
n A
Av
ve
e..,, IIrrv
viin
ne
e,, C
CA
A
9
92
26
60
06
6--5
50
02
27
7
1
1--8
80
00
0--S
SM
MA
AR
RT
TH
HO
OM
ME
E ((8
80
00
0--7
76
62
2--7
78
84
46
6)) w
ww
ww
w..s
sm
ma
arrttlla
ab
bs
siin
nc
c..c
co
om
m
SmartLabs Product Number
2412S – Power Line Modem Module
Warranty
2 years
Software:
Sold Separately
Operation Modes
INSTEON only, X10 only, INSTEON and X10 Combo Mode
Connector Type
RJ-45
Interface
RS-232 & TTL & 12VDC (unregulated) @ 300mA
INSTEON Addresses
1 hard-coded out of 16,777,216 possible
INSTEON Links
417 out of 16,777,216 possible
INSTEON Device Category
0x03 (Network Bridges)
INSTEON Device Sub-Category
0x05
INSTEON Powerline Frequency
131.65 KHz
Minimum Transmit Level
3.2 Vpp into 5 Ohms
Minimum Receive Level
20 mVpp nominal
INSTEON Messages Repeated
Yes
X10 Powerline Frequency
121 KHz
X10 Messages Repeated
No
Operating Conditions
Indoors, 40 to 132°F, up to 85% relative humidity
Physical
3.9" H x 2.6" W x 1.5" D - 9.6 oz
Supply Voltage
120 Volts AC +/- 10%, 60 Hertz, single phase
Surge Protection
MOV rated for 150 Volts
Pass-through outlet
Un-controlled 3-prong (with ground) 120V, 15 amps
Certification
Safety tested for use in USA and Canada (ETL #3017581)
Electrical
Mechanical
General
Operation
Interface
Features
Specifications
®