background image

Serial and TTL Interface (#2413S)

Quick-Start Guide

POWERLINC

TM

MODEM - INSTEON SERIAL INTERFACE (DUAL BAND)

N

Ne

ee

ed

d  H

He

ellp

p?

?  F

Fo

orr  a

as

ss

siis

stta

an

nc

ce

e  c

ca

allll  yyo

ou

urr  ffrriie

en

nd

dllyy  

s

su

up

pp

po

orrtt  p

pe

errs

so

on

n  @

@  8

80

00

0--7

76

62

2--7

78

84

46

6

Tips for Using PowerLinc Modem

• Do not plug PowerLinc Modem into a power strip or AC line filter.

• Some computers and their accessories can absorb PowerLinc Carrier (PLC) signals off the power lines.

Since PowerLinc Modem will be so close to the computer, 

the power strip for the computer should be

filtered.

Use Smarthome’s FilterLinc

TM

#1626 on the computer’s power strip to keep the PowerLinc

Modem’s signals from getting absorbed by the computer equipment.

• Don't plug other PLC transmitters into the same outlet as PowerLinc Modem. Every PLC transmitter will

absorb the other transmitter's PLC signals when they are not transmitting. In some cases, up to half
the signal can be lost due to nearby transmitters.

• If the computer's serial port is shared with another hardware device (scanner, pda, etc.) be sure to turn

off that device's program on the PC.  If left running, the home automation software will not be able to
communicate to the PowerLinc Modem.

#1626 FilterLinc

TM

Plug-In Filter

Specifications

G

Ge

en

ne

erra

all

SmartLabs Product Number

2413S - PowerLinc Modem Module

Warranty:

2 years

Software:

Sold Separately

O

Op

pe

erra

attiio

on

n

Operation Modes

INSTEON only, X10 only, INSTEON and X10 Combo Mode

Interface

Connector Type

RJ-45

Interface

RS-232 & TTL

F

Fe

ea

attu

urre

es

s

INSTEON Addresses

1 hard-coded out of 16,777,216

INSTEON Links

2016 out of 16,777,216 possible 

INSTEON Device Category

0x03 (Network Bridges)

INSTEON Device Sub-Category

0x11

INSTEON Powerline Freequency

131.65 kHz

Minimum Transmit Level

3.2 Vpp into 5 Ohms

Minimum Receive Level

20 mVpp nominal

INSTEON Messages Repeated

Yes

X10  Powerline Frequency

121 kHz

X10 Messages Repeated

No

M

Me

ec

ch

ha

an

niic

ca

all

Operating Conditions

Indoors, 40 to 132 F, up to 85% relative humidity

Physical

3.9” H x 2.6” W x 1.5” D x 9.6 oz

E

Elle

ec

cttrriic

ca

all

Supply Voltage

120 Volts AC +/- 10%, 60 Hertz, single phase

Pass-through outlet

Un-controlled 3-prong (with ground) 120V, 15 amps

Certification

Safety tested for use in USA and Canada (ETL #3017581)

S

Sm

ma

arrttL

La

ab

bs

s  L

Liim

miitte

ed

d  W

Wa

arrrra

an

nttyy

SmartLabs warrants to the original consumer of this product that, for a period of one year from the date of purchase, this product will be free from defects in material and workmanship and will perform
in substantial conformity to the description of the product in the owner's manual.  This warranty shall not apply to defects or errors caused by misuse or neglect.

IIN

NS

ST

TE

EO

ON

N  a

an

nd

d  T

Th

he

e  IIN

NS

ST

TE

EO

ON

N C

CO

OM

MP

PA

AT

TIIB

BL

LE

E llo

og

go

o  a

arre

e  ttrra

ad

de

em

ma

arrk

ks

s  o

off  S

Sm

ma

arrttL

La

ab

bs

s,,  IIn

nc

c..  U

U..  S

S..  P

Pa

attn

ntt  N

No

o..  7

7,,3

34

45

5,,9

99

98

8  ©

©  C

Co

op

pyyrriig

gh

htt  2

20

00

09

9  S

Sm

ma

arrttL

La

ab

bs

s,,  1

16

65

54

42

2  M

Miilllliik

ka

an

n  A

Av

ve

e..,,  IIrrv

viin

ne

e,,  C

CA

A  9

92

26

60

06

6--5

50

02

27

7  

8

80

00

0--7

76

62

2--7

78

84

46

6  w

ww

ww

w..s

sm

ma

arrttlla

ab

bs

siin

nc

c..c

co

om

m

rev. 090108

FCC Compliance Statement

This device complies with FCC Rules Part 15.

Operation is subject to two conditions: 

((1

1)) This device may not cause harmful interference,

and

((2

2)) this device must accept any interference that

may be received or that may cause undesired
operation.  The digital circuitry of this device has
been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the
FCC Rules.  These limits are designed to provide
reasonable protection against harmful interference
in residential installations.  This equipment
generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance
with the instructions, may cause harmful
interference to radio and television reception.
However, there is no guarantee that interference
will not occur in a particular installation.  If this
device does cause such interference, which can be
verified by turning the device off and on, the user is
encouraged to eliminate the interference by one or
more of the following measures:
•Re-orient or re-locate the receiving antenna of the
device experiencing the interference.
•Increase the distance between this device and the
receiver.
•Connect the device to an AC outlet on a circuit
different from the one that supplies power to the
receiver.
•Consult the dealer or an experienced radio/TV
technician.
W

WA

AR

RN

NIIN

NG

G!!   Changes or modifications to this unit

not expressly approved by the party responsible for
compliance could void the user's authority to
operate the equipment.

Reviews: