background image

Four-Faith Smart Power Technology Co., Ltd.

F1203 CDMA MODEM

USER MANUAL

Summary of Contents for F1203

Page 1: ...Four Faith Smart Power Technology Co Ltd F1203 CDMA MODEM USER MANUAL ...

Page 2: ...enefits 3 1 3 Working Principle 3 1 4 Specifications 4 Chapter 2 Installation Introduction 5 2 1 General 5 2 2 Encasement List 5 2 3 Installation and Cable Connection 5 2 4 Power 6 2 5 Indicator Lights Introduction 6 Chapter 3 Dial Up Settings 7 3 1 MODEM Connection 7 3 2 Dial Up Settings 7 Chapter 4 SMS Test 19 Chapter 5 Appendix 21 ...

Page 3: ...er and so on 1 2 Features and Benefits Design for Industrial Application High powered industrial cellular module Housing iron providing IP30 protection Power range DC 5 35V Stability and Reliability RS232 port 15KV ESD protection SIM UIM port 15KV ESD protection Power port reverse voltage and overvoltage protection Antenna port lightning protection optional Standard and Convenience Support standar...

Page 4: ...ndicator Power ACT Online Antenna Standard SMA female interface 50 ohm lighting protection optional SIM UIM Standard 3V 1 8V user card interface 15KV ESD protection Power Standard 3 PIN power jack reverse voltage and overvoltage protection Power Input Item Content Standard Power DC 12V 1 5A Power Range DC 5 35V Consumption 200mA 12V Physical Characteristics Item Content Housing Iron providing IP30...

Page 5: ... Certification card 1 Maintenance card 1 2 3 Installation and Cable Connection Dimension unit mm 58 5 35 28 28 22 8 25 Ф3 Ф5 4 Installation of SIM UIM card Firstly power off the MODEM and press the out button of the SIM UIM card outlet with a needle object Then the SIM UIM card sheath will flick out at once Put SIM UIM card into the card sheath Pay attention to put the side which has metal point o...

Page 6: ...ata cable is as follows 2 4 Power The power range of the MODEM is DC 5 35V Warning When we use other power we should make sure that the power can supply power above 4W We recommend user to use the standard DC 12V 0 5A power adaptor 2 5 Indicator Lights Introduction The MODEM provides three indicator lights Power ACT Online Indicator Light State Introduction Power ON MODEM is powered on OFF MODEM i...

Page 7: ...d Chapter 3 Dial Up Settings 3 1 MODEM Connection Connect Modem and PC with the shipped RS 232 cable as following 3 2 Dial Up Settings 1 Press start Settings Control Panel Double click Phone and Modem Options 2 Choose Modems Press Add button ...

Page 8: ...aith Smart Power Technology Co Ltd 3 Choose Don t detect my modem I will select it from a list and click Next 4 Manufacture choose Standard Modem Types Models choose Standard 33600 bps Modem click Next button ...

Page 9: ...Four Faith Smart Power Technology Co Ltd 5 Selected ports choose the actual COM port which connects to Modem click Next button 6 Click Finish button return back to Modems page ...

Page 10: ...Four Faith Smart Power Technology Co Ltd 7 Choose the modem you have just installed click properties button to configure the modem driver ...

Page 11: ...Four Faith Smart Power Technology Co Ltd 8 Choose Modem page set Maximum Port Speed as 115200 9 Choose Advanced page click Change Default Preferences button ...

Page 12: ...ower Technology Co Ltd 10 Port Speed choose 115200 Flow control choose None click OK button 11 On the Advanced page click OK button return to Phone and Modems page click OK button to finish the Modem driver installation ...

Page 13: ...Four Faith Smart Power Technology Co Ltd 12 Finish installing Modem driver It s necessary to install the Dial Up connection Open Control Panel double click Network connections ...

Page 14: ...wer Technology Co Ltd 13 Click Create a new connection to start creating a new Dial Up connection 14 Click Next button 15 Choose Connect to the Internet click Next button 16 Choose Set up my connection manually click Next ...

Page 15: ...Four Faith Smart Power Technology Co Ltd 17 Choose Connect using a dial up modem click Next 18 Choose the Modem driver installed just now click Next button 19 Input the ISP Name click Next button ...

Page 16: ...your ISP In China It is 777 click Next button 21 Input the username and password In China they are both card Click Next 22 Choose Add a shortcut to this connection to my desktop click Finish button 23 Double click the Dial Up shortcut on your desktop to run Dial Up program ...

Page 17: ...Technology Co Ltd 24 Click the Properties button of the Dial Up program 25 Choose the Modem driver installed before Click Configure button 26 Set Maximum Speed bps as 115200 set Hardware features as following click OK button ...

Page 18: ...Faith Smart Power Technology Co Ltd 27 Click OK button to finish Dial Up program configuration 28 Click Dial button to start dial 29 When dial success There is a connection icon on the right of your taskbar ...

Page 19: ...I functions The following describes how to test the SMS function 1 Connect PC and Modem with the shipped RS 232 cable and power on Modem The connection diagram please refer chapter 3 1 2 Run FfSmsTestTool En exe 3 Choose the COM port which connect to MODEM baud rate is 15200 click Start button 4 The tool will initiate Modem after clicking the Start button If initiate success the log column will sh...

Page 20: ...Four Faith Smart Power Technology Co Ltd 6 The result state will display in the Log column 7 When received SMS It will display in the receive column 8 Complete SMS test ...

Page 21: ...send AT command to modem with it 1 Press Start Programs Accessories Communications Hyper Terminal 2 Input connection name choose OK 3 Choose the correct COM port which connects to modem choose OK 4 Configure the serial port parameters as following choose OK Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow control None ...

Page 22: ...Four Faith Smart Power Technology Co Ltd 5 Complete Hyper Terminal operation It runs as following 6 Type AT in the blank of Hyper Terminal and press Enter the modem will return ok ...

Reviews: