Set 

Button 

Quick-Start Guide

 

OutletLinc

 – INSTEON

®

 Remote Control  

Dimmer Outlet (Dual-Band) 

Model: 2472D  

Preparation

 

Installation should be performed only by a qualified electrician or by a 
homeowner who is familiar and comfortable with electrical circuitry. If 
you have any questions regarding installation, we suggest consulting an 
electrician. If you have any questions regarding setup, contact the 
INSTEON Gold Support Line. 

Tools Needed 

  Phillips and standard screwdrivers 

  Wire cutter / stripper 

  Voltage tester to identify wires inside 

the junction box 

Introduction

 

OutletLinc brings the power of INSTEON into your home, allowing you 
to remotely control and dim any device plugged directly into the top 
outlet.  
OutletLinc also works as an INSTEON signal repeater and can be used 
to bridge the power phases in your home (like an Access Point, #2443). 
Use indoors only with incandescent loads up to 300 Watts.  

Controlled 
receptacle 

Status

LED 

Uncontrolled 

receptacle 

Installation Instructions 

1) 

At the circuit breaker or fuse panel, disable the circuit supplying power to the outlet 

2) 

Remove the existing wallplate from the outlet you are replacing. Then, unscrew the outlet itself and pull it out from 
the junction box. 

3) 

Disconnect the wires from the outlet you are replacing and ensure that you have ½ inch of bare wires on the ends 

4) 

To correctly identify the outlet’s LINE, NEUTRAL, and GROUND wires, enable power to the outlet from the circuit 
breaker or use a line voltage meter, and then turn the breaker off again 

5) 

Twist together the bare copper OutletLinc wire to the outlet’s GROUND wire with an included wire nut 

6) 

Twist together the white OutletLinc wire to the outlet’s NEUTRAL wire (usually white) with an included wire nut 

7) 

Twist together the black OutletLinc wire to the outlet’s LINE wire with an included wire nut 

8) 

Ensure all the wire connectors are firmly attached and that there is no exposed copper except for the GROUND 
wire 

9) 

Carefully install OutletLinc into the electrical box and replace the wallplate 

10) 

Enable power to the outlet from the circuit breaker or fuse panel  

The OutletLinc Status LED should turn on solid red  

11) 

Attach the included Outlet Dimmer Key to the plug of the load you wish to 
control with the magnet at the bottom. The flat side of the key should face 
away from the prongs of the plug (so the key will lay flush against 
OutletLinc when the load is plugged in).  

 

12) 

Plug the load into the top outlet on OutletLinc 

The load should turn on and the OutletLinc Status LED should turn on solid green 

 

13) 

If the load does not turn on, turn it on manually using the switch on the load itself 

OPTIONAL: You can use the bottom outlet on OutletLinc as you would and ordinary outlet. 

 

To control the load, you will need to Link OutletLinc to an INSTEON Controller (see 

Linking OutletLinc as a 

Responder

). You will not be able to control the load from OutletLinc itself. See the Controller’s Owner’s Manual for 

instructions on how to control OutletLinc. 

 

NOTE: You will not be able to control the load from the manual switch. Make sure the load’s manual switch is always in 
the on position. Otherwise, the load will not receive INSTEON communications.  