background image

Page 1 of 13  

     

2634-222 - Rev: 2/11/2019 9:16 AM 

 

On/Off Outdoor Module  

Owner’s Manual 

2634-222 

 

 

 
 

 

Summary of Contents for 2634-222

Page 1: ...Page 1 of 13 2634 222 Rev 2 11 2019 9 16 AM On Off Outdoor Module Owner s Manual 2634 222...

Page 2: ...rollers Responders and Links 6 Make On Off Outdoor Module a Responder 6 Make On Off Outdoor Module a Controller 6 Groups 7 Scenes 7 Remove On Off Outdoor Module as a Responder 7 Remove On Off Outdoor...

Page 3: ...s and links to other INSTEON devices in minutes Controls standard incandescent loads up to 1440 Watts and inductive loads up to 12 Amps Weatherproof to withstand harsh outdoor conditions Indicates INS...

Page 4: ...GFCI device Don t bury On Off Outdoor Module any electrical cable or component connected to it A buried power cord may result in electrocution if improper cables are used or if digging occurs over the...

Page 5: ...ntroller On Off Outdoor Module LED will blink green for INSTEON traffic and if it detects noise that could disrupt communication Programming Lock Default disabled This setting is only adjustable via s...

Page 6: ...ad to desired state on or off 3 Press and hold On Off Outdoor Module set button until it double beeps Controller will double beep and its LED will stop blinking 4 Test link by tapping controller butto...

Page 7: ...as a member 1 Press and hold controller set button until it beeps Controller LED will start blinking green 2 Tap controller set button Controller LED will start double blinking green 3 Use On Off Modu...

Page 8: ...ing is disabled on On Off Outdoor Module by default but you can enable it by following these steps Enable Load Sensing 1 Press and hold On Off Outdoor Module set button until it beeps 3 seconds On Off...

Page 9: ...400 LED Green when load is on red when load is off Blinks red or green during setup Beep on button press No Local control Yes Commands supported as controller On Off Commands supported as responder On...

Page 10: ...ng temperature range 4 to 122 F 20 to 50 C Storage temperature range 4 o to 158 o F 20 o to 70 o C Operating humidity range 0 90 relative humidity Electrical Voltage 120 Volts AC 10 Frequency 60Hz Loa...

Page 11: ...to a controller The controller may be sending commands to a responder that is no longer in use Commands for the unused responder are being resent and loading down the signal Unlink any unused responde...

Page 12: ...evice does not provide a phase bridge to Micro module Relocate if necessary and practical If the other dual band device is not blinking Device is not within RF range of Micro module so it does not pro...

Page 13: ...lament de tungstene afin de reduire le risqu de surchauffe et la possibilite d endommagement a d autres materiels ne pas installer pour commander une prise un appareil a moteur une lampe fluorescente...

Reviews: