background image

2453-222/2453-422/2453-522 Rev. 8/13/2012 9:25 AM / See Owner’s Manual for Warranty Information. 
Protected under U.S. and foreign patents (see 

www.insteon.com

© Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845 

 
 

To determine DIN Rail module’s current switch operation mode, simply tap Set button: 

 

If it beeps, DIN Rail module is configured for a single momentary switch 

 

If it double-beeps, DIN Rail module is configured for a dual momentary switch 

 

If it triple-beeps, DIN Rail module is configured for a latching switch (default) 

Change

 to Single Momentary Mode 

1)  Press and hold Set button until it beeps 

LED will start blinking green

 

2)  Press and hold Set button until it beeps again 

LED will start blinking red

 

3)  Press and hold Set button until it beeps a third time 

LED will start blinking green

 

4)  Slowly tap Set button four times 

LED will continue blinking green

 

5)  Press and hold Set button until it double-beeps 

LED will stop blinking

 

6)  Test mode change by tapping switch on and off 

Load will respond appropriately 

 

Change to Dual Momentary Mode 

1)  Press and hold Set button until it beeps 

LED will start blinking green

 

2)  Press and hold Set button until it beeps again 

LED will start blinking red

 

3)  Press and hold Set button until it beeps a third time 

LED will start blinking green

 

4)  Slowly tap Set button five times 

LED will start double-blinking green

 

5)  Press and hold Set button until it double-beeps 

LED will stop blinking

 

6)  Test mode change by tapping switch top and bottom 

Load will respond appropriately 

 

Change to Latching Mode (default) 

1)  Press and hold Set button until it beeps 

LED will start blinking green

 

2)  Press and hold Set button until it beeps again 

LED will start blinking red

 

3)  Press and hold Set button until it beeps a third time 

LED will start blinking green

 

4)  Slowly tap Set button six times 

LED will continue blinking green

 

5)  Press and hold Set button until it double-beeps 

LED will stop blinking

 

6)  Test mode change by tapping switch on and off 

Load will respond appropriately

 

 

Make DIN Rail On/Off a Responder 

1)  Press and hold controller Set button until it beeps 

Controller LED will start blinking green

 

2)  Adjust load connected to DIN Rail module to desired level 

3)  Press and hold DIN Rail module Set button until it double-beeps 

Controller will double-beep and its LED will stop blinking

 

Reviews: