8) After ensuring wires are firmly connected and that there is no exposed wire, turn on breaker/fuse
Load will turn on and DIN Rail module LED will turn on green
9)
Test connection by tapping DIN Rail module paddle top and bottom
Load will turn on and off
10) If you are installing a single momentary or dual momentary switch, follow the instructions in
Switch Operation
Mode
below to program the correct mode for your switch
11) If you are planning to manually link DIN Rail module to any INSTEON devices, do so now (see
Make DIN Rail
Module a Responder
and
Make DIN Rail Module a Controller
below)
12) Test installation by tapping switch connected to DIN Rail module on and off
Load will turn on and off
Switch Operation Mode
By default, DIN Rail module is programmed for a latching switch. Program the switch operation for single momentary
mode, dual momentary mode or back to latching mode according to your switch type.