ccessPoint Installation Tips 

 strip or AC line filter. 

m within communication range of 

 homes, locate AccessPoints on different floors. 

 a refrigerator, cabinet, or television.  

ot process X10 traffic.  In the design of your 

N devices, you should properly install 

at least two 

AccessPoint is intended for installation in accordance with the National Electric Code and local regulations in the United 
States, or the Canadian Electrical Code and local regulations in Canada.  Use indoors only.  AccessPoint is not 
designed nor approved for use on power lines other than 120V 60Hz, single phase.  Attempting to use AccessPoint on 
non-approved powerlines may have hazardous consequences. 

Read and understand these instructions before installing, and retain them for future reference. 

Caution 

 

Proper installation of at least two AccessPoints is recommended prior to 
installing and using other INSTEON devices. 

A

 

Do not plug AccessPoint into an outlet controlled by a switch, because if the switch is inadvertently 
turned off, AccessPoint will not have power. 

 

Do not plug AccessPoint into a filtered power

  Locate AccessPoints in different areas of the home, keeping the

each other. 

 

In multi-level

  Do not place AccessPoint near large metal objects, like

AccessPoint works best when placed out in the open. 

  Unlike many INSTEON devices, AccessPoint does n

home automation network, understand that AccessPoint will 

not

 provide the same benefits for your 

X10 devices (signal repeating and phase bridging) that it does for INSTEON devices. 

Installing the First Two AccessPoints 

Prior to setting up and using other INSTEO
AccessPoints, so that INSTEON messages can travel everywhere in your home.  AccessPoints (when at 
least two are properly installed) couple together the two separate powerline circuits, known as 

powerline 

phases

, which most homes are wired with.  Please see 

AccessPoint Installation Tips

 above for more 

information and guidelines on optimizing your installation.  You can add more AccessPoints as needed for 
superior performance and maximized coverage of your INSTEON network.  

Page 4 of 12 

 

Summary of Contents for 2443

Page 1: ...INSTEON AccessPoint INSTEON RF Receiver RF PLC Bridge For models 2443 AccessPoint 2443P AccessPoint two pack ...

Page 2: ...stall the AccessPoint 5 Install the Second AccessPoint or any subsequent AccessPoints 5 Installing Additional AccessPoints 6 ABOUT INSTEON 7 Understanding Why an INSTEON Network Is Reliable 7 Further Enhancing Reliability 7 Using SmartLabs AccessPoint to Upgrade Your INSTEON Network 7 About INSTEON and X10 8 TROUBLESHOOTING 9 SPECIFICATIONS 10 AccessPoint Specifications 10 FCC Compliance Statement...

Page 3: ... is a breeze and there are no wires to add INSTEON uses existing powerline wiring as well as radio frequency for communication Reliable because every INSTEON device is a two way repeater And affordable not just because of low cost but because INSTEON also works with legacy X10 devices An INSTEON home grows in value with every INSTEON device you add making life more convenient safe and fun Key Acce...

Page 4: ... plug AccessPoint into an outlet controlled by a switch because if the switch is inadvertently turned off AccessPoint will not have power Do not plug AccessPoint into a filtered power Locate AccessPoints in different areas of the home keeping the each other In multi level Do not place AccessPoint near large metal objects like AccessPoint works best when placed out in the open Unlike many INSTEON d...

Page 5: ...nto Setup Mode and you will have another 9 minutes 2 Locate another unswitched outlet preferably on the other side of your home and plug the Second AccessPoint into it 3 Observe the Status LED on the Second AccessPoint Bright and Steady Blink or Dim A If the Status LED is bright and steady the two AccessPoints are communicating with each other and plugged into outlets on opposite powerline phases ...

Page 6: ...g Additional AccessPoints You can add additional AccessPoints to your INSTEON network to extend its coverage and maximize performance Simply choose the AccessPoint that you previously installed as the First AccessPoint and follow the steps above to confirm that new AccessPoints are communicating with your existing AccessPoints After the two opposite powerline phases in your home are coupled with a...

Page 7: ... way to overcome signals getting weaker is to increase the coverage of the mesh network by introducing more INSTEON devices It is possible that TVs PCs power strips or other electrical equipment may attenuate INSTEON signals on the powerline You can temporarily unplug suspected devices to test whether the INSTEON signal improves If it does then you can plug in filters such as SmartLabs FilterLinc ...

Page 8: ...or turn off when you set the X10 Address for the product If turned on the BoosterLinc technology may INSTEON interfere with 1 Press and hold the SET Button 2 Send the X10 Primary Address 3 Send an X10 OFF Command You can send an X10 ON Command in Step 3 to re enable the BoosterLinc feature To disable BoosterLinc X10 Signal Boosting on these products NOTE KeypadLinc 6 with Integrated Dimmer 12073W ...

Page 9: ...tried several outlets and the Second AccessPoint s Status LED is blinking or steadily on at dim level Something made of metal is blocking the wireless signal Move AccessPoints away from metal objects The Status LED has turned off and does not flicker during INSTEON transmissions A surge or excessive noise on the powerline may have locked up AccessPoint Unplug AccessPoint for 10 seconds and reinsta...

Page 10: ...er SBP2443 INSTEON Powerline Features INSTEON Powerline Frequency 131 65 KHz INSTEON Minimum Transmit Level 3 2 Vpp into 5 Ohms INSTEON Minimum Receive Level 1 mVpp nominal INSTEON Messages Repeated Yes X10 Features X10 Messages Repeated No Mechanical Operating Conditions Indoors 0 to 70 C up to 85 relative humidity Dimensions 4 0 H x 2 5 W x 1 25 D Weight 3 6 oz Electrical Supply Voltage 120 Volt...

Page 11: ...uency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio and television reception However there is no guarantee that interference will not occur in a particular installation If this device does cause such interference which can be verified by turning the device off and on the user is encouraged to eliminate the interference by one or mo...

Page 12: ...uct with the RA clearly printed on the outside of the package and send the product along with all other required materials to SmartLabs Inc ATTN Receiving Dept 16542 Millikan Ave Irvine CA 92606 5027 Limitations The above warranty is in lieu of and seller disclaims all other warranties whether oral or written express or implied including and warranty or merchantability or fitness for a particular ...

Reviews: