4
-EN
Ӽ Dip Switch
DIP1
DIP2
DIP3 DIP4 DIP6
DIP5
ON: LED signals alarm events (
default
)
OFF: LED is deactivated during alarm
PIR Sensitivity Switch
ON: Standard sensitivity needs more then one detection to
trigger an alarm to minimize false positives (factory default)
OFF: Deactivate false alert compensation for a higher
sensitivity.
These switches are not used.
LED Status during Alarm
ON:
AND Mode
- both Microwave and PIR have to
detect a motion to trigger an alarm (factory default)
OFF:
OR Mode
- either PIR or Microwave can trigger
an alarm.
Ӽ Tamper Switch
Use is OPTIONAL
Tamper Switch
The Tamper switch protects the enclo-
sure against unauthorized opening or
sabotage. To use the Tamper switch,
please make sure to bridge C1/ T2 with
NC and connect T1 & C to the
NC
operated alarm input of your camera.
Pls check
http://motion500.instar.com
for more details.