Top-up feature:
•
At the end of the timed dispense cycle, the “CAUTION” message will continue to flash for a
further 5 seconds. During this 5-second window, the water level in the cup or teapot can be
topped-up by simply pressing & holding the dispense button.
NOTE
: Once the “CAUTION” message stops flashing, the top
-up facility ends and the boiler
reverts back to timed dispense mode.
8.0 - SERVICE WARNINGS AND FAULT DIAGNOSIS
Your boiler is fitted with an intelligent fault diagnosing system and is able to detect various fault
conditions. Some of these are less serious and the machine will continue to operate as normal,
while others are more serious and will disable the unit.
Before calling for service, switch the machine off at the mains supply and then switch back on after
10 minutes. If the fault does not clear, call technical support for advice.
SCREEN MESSAGE
POSSIBLE CAUSES:
ACTION;
R E A D Y
CHECK WATER
WHITE SCREEN
•
Water turned off
•
Inlet hose kinked or
bent
•
Low in-coming water
pressure
•
Check water supply
and stop-cock
•
Check in-coming water
is at minimum of 2-bar
R E A D Y
CLEAN PROBES
WHITE SCREEN
•
Low-water level probe
scaled up
•
De-scale inside of tank
and level sensors
N O T R E A D Y
OF
RED SCREEN - FLASHING
WITH WARNING TRIANGLES
•
Normal operating probe
has scaled up
•
De-scale level sensors
N O T R E A D Y
TH
RED SCREEN
–
FLASHING WITH
WARNING TRIANGLES
•
Over-boiled (due to
excessive lime-scale in
tank).
•
Faulty Element
•
Thermistor
disconnected, wires cut
or faulty
•
Boil-dry safety switch
tripped or faulty
•
De-scale
tank
and
level-sensors
•
Isolate machine and
wait 10mins, then turn
back on again.
•
Reduce
temperature
setting
•
Call service if fault
persists.
9.0 - CLEANING
The external surfaces of the water font can be kept clean by wiping with a damp cloth. Do not use
abrasive material on the outer surface of the machine.