6.0 - OPERATION 

 

IMPORTANT:  DO  NOT  SWITCH  MACHINE  ON  UNTIL  INSTALLATION  IS  COMPLETE  AND  ALL 
ELECTRICAL/PLUMBING CONNECTIONS HAVE BEEN MADE. 

 

 

Switch machine on by pressing the small button at the top of the  display panel [under-counter 

unit]. The boiler will run through an initial self diagnostic check and various messages will display 
within  the  window.  Providing  the  water  supply  is  present,  the  machine  will  start  to  fill  and  the 
message 

“BOILER FILLING”

 will be displayed.  

 

(If  the  machine  does  not  fill  to  its  pre-set  level  within  6  minutes  the  display  will  read 

“NO  WATER”

.  If  this 

happens, check that the water stop valve is turned on and there are no kinks in the inlet hose. If these are in 
order, check that the small plastic filter in the water connection point on the machine is not clogged with 
debris. To clear the warning, switch the machine off at the mains and then back on again). 

 

●When  the  water  level  reaches  the  boiler’s  bottom  sensor,  the  heater  will  be  switched  on.  The 

display will read 

“BOILER HEATING”.

 

When the correct temperature has been reached, the display will read 

“BOILER READY” 

and the 

green tick in the display will illuminate. In addition, the water font button will illuminate RED     
 
IMPORTANT NOTE: In daily use you may use the boiler as soon as the water font button illuminates 
RED - BUT ON FIRST INSTALLATION YOU SHOULD WAIT AT LEAST 10 MINUTES BEFORE STARTING 
TO USE THE WATER. 
 

Your machine will not fill completely at once. The water input is electronically controlled to obtain 

maximum output, temperature and efficiency. 
 
IN DAILY USE - switch on and wait for the water font push-button to illuminate RED. The water will 
then be at the correct temperature. 

 

To dispense hot water, place cup on drip-tray and press button.    

 

 

7.0 - 

OPTIONAL “TIMED” DISPENSE:

 

 

This function is appropriate when the cup/teapot being filled is always the same size/capacity. 

 

To change boiler from “on

-d

emand” default setting to “Timed” dispense: 

 

 

 

Switch off on front of unit 

 

Unplug from mains power supply and wait 10 seconds. 

 

Plug boiler back in and at the same time, press & hold the dispense button for 5 seconds.  
Boiler will either start to fill with water or the dispense button will begin to flash (depending 
on water level in tank). 

 

Place vessel on drip-tray 

 

Press & hold the dispense button to fill vessel to the required level. Release button to stop 
dispense (NOTE: This can be repeated as many times as necessary, to get the level 
correct).    

 

Once level in vessel is correct, press the ON/OFF button (below display) to save the 
measured dispense amount (this saves the setting and puts the boiler into standby mode).  

 

To continue, switch boiler back on by pressing the ON/OFF button again. 

 

The boiler will now dispense the measured amount into the cup/teapot, each time the 
button is pressed. 

 
 
 
 
 

Summary of Contents for InstaTap UCB Series

Page 1: ...UCB Series Single Font Units InstaTap Under Counter Push Button Dispenser INSTALLATION USER INSTRUCTION MANUAL IB24 S...

Page 2: ...lpful in notifying users that the appliance contains and dispenses near boiling water During normal use of the boiler all surfaces remain cool However care should be taken to avoid potential injury fr...

Page 3: ...ze H x W x D 502 x 254 x 440 Voltage 220 240V single phase 50 60Hz Supply AC Rated Input 3 0kW Output Amps 13A Fill Type Automatic Max Rapid Draw Off 10 Litres 50 x 200ml 7oz cups Recovery per Minute...

Page 4: ...exceeding 7 bar 96psi and no lower than 2 bar 28psi If your water pressure exceeds 7 bar a suitable pressure reduction valve may need to be fitted to the water supply to bring the pressure to a level...

Page 5: ...anent waste or drain then the mains water supply to the boiler should be isolated and the unit switched off whenever it is left unattended for long periods e g overnight IMPORTANT Whilst reasonable pr...

Page 6: ...n illuminates RED BUT ON FIRST INSTALLATION YOU SHOULD WAIT AT LEAST 10 MINUTES BEFORE STARTING TO USE THE WATER Your machine will not fill completely at once The water input is electronically control...

Page 7: ...l technical support for advice SCREEN MESSAGE POSSIBLE CAUSES ACTION R E A D Y CHECK WATER WHITE SCREEN Water turned off Inlet hose kinked or bent Low in coming water pressure Check water supply and s...

Page 8: ...Any scale which is difficult to remove can be dissolved by using a solution of Renegite de scaler Wipe clean the level sensing probes Ensure all traces of de scaler are removed before replacing tank...