background image

10. Drain-off approximately 10 litres of water 

  (to flush new filter cartridge through).

11.  TO RESET FILTER-LIFE MONITOR: …Press 

and hold “On/Off” button for 10 seconds, 

screen will go blank before changing to red 

and displaying message “FILT 0000 LITRES” 

to confirm it has been reset.

The boiler is now ready for use.

Adjusting Filter Monitor 
(Optional):

The filter-life monitor is factory-set to 9001 litres 

(default) which is suitable for most parts of the 

UK with average or medium water hardness.  

 

Hard and Soft Water: The effectiveness of 

the filter will be reduced in hard water areas 

(and should be replaced more frequently), or 

extended in soft water areas where scale is less 

of a problem.  

If in doubt as to the hardness of water 
supplied in your area, consult your local 
water authority or Instanta Technical 
Support.

The filter-life monitor can be changed from the 

default setting, to suit the local water conditions 

in your area. As an example; locations with soft 

water might set the monitor between 11,000 to 

14,000 litres, whereas locations with particularly 

hard water may choose to set between 5,000 to 

7,000 litres.      

To adjust filter-life monitor (optional);
Replace the filter cartridge (as steps 1 to 10 

“AQ35 Filter Replacement” above). Then;

•  With machine turned off, press & hold ON/

OFF button (for approximately 7 seconds) 

until Yellow screen shows “USER PROG”, 

then release button.   

•  Advance through the menu options by 

pressing the ON/OFF button (short pushes), 

until “FSIZ” option is displayed.

•  Press & hold button (long push) so screen 

displays filter size in litres.

•  To change the litres setting, press ON/OFF 

button (short pushes) until desired filter size 

in litres is displayed (advances in 500 litre 

increments).

•  To save new litres setting, press ECO button 

(short push & release).

•  To exit USER menu, press & hold ECO 

button (long push – 5 seconds) then release. 

Screen will show “WAIT” whilst any changes 

are being saved, then go blank.

•  Turn machine back on again.
•  TO RE-SET & CONFIRM NEW SETTINGS; 

…Press and hold ON/OFF button for 

10 seconds, screen will go blank before 

changing to Red and displaying message 

“FILT 0000 LITRES” to confirm it has been 

reset (See step 11 above). 

 

 

 

 

 

 

7

Summary of Contents for CPF210

Page 1: ...PF210 CPF310 CPF510 CPF520 3 CPF520 6 Auto Fill Catering Water Boiler with Integrated Multi Filter Installation and User Instructions The Professional s Choice INSTANTA LIMITED Canning Road Southport...

Page 2: ...NING 9 MAINTENANCE SPARES SERVICE INFORMATION 9 SERVICE WARNINGS FAULT DIAGNOSTICS 9 10 SERVICE TECHNICAL SUPPORT 11 GUARANTEE 11 Introduction Dear Customer Thank you for purchasing this Instanta prod...

Page 3: ...Electrical Electronic Equipment The crossed out wheelie bin symbol on this product means that discarded electrical and electronic products should not be mixed with general waste Disposing of the prod...

Page 4: ...ke this work Overflow The drip tray has a limited capacity and is designed to handle small spillages and drips Wherever possible we strongly recommend that it is connected to a permanent waste We have...

Page 5: ...NOT READY HEATING When the correct temperature has been reached the display will change from Red to White and will simply read READY The boiler will then continue in a heat fill cycle until the tank...

Page 6: ...sures that water is always to the highest standard whilst delivering lower maintenance costs and improved energy efficiency Quick and easy to change the new filter reduces sediment chlorine taste odou...

Page 7: ...of the new filter and push the two together until it clicks firmly in place 7 Remove protective cap from the top of the new cartridge and ensure the two rubber seals are in place 8 Insert new cartrid...

Page 8: ...set the monitor between 11 000 to 14 000 litres whereas locations with particularly hard water may choose to set between 5 000 to 7 000 litres To adjust filter life monitor optional Replace the filte...

Page 9: ...elect There are three options to choose ALL set ON and OFF times once and they apply to the full 7 day week ON set the ON and OFF times separately for each day of the week OFF Default the timer is dis...

Page 10: ...re using the boiler again Replace evaporation plates tank lid and outer lid Draw off tap The draw off tap components are subject to wear tear We strongly recommend that the tap is inspected periodical...

Page 11: ...10 To reset boiler safety controls Safety Caution Isolate boiler from power supply before removing any outer panels or attempting any reset...

Page 12: ...g exclusions Problems caused by hard water and lime scale We regret that we cannot be held responsible for problems caused by hard water Dripping Taps These components are subject to wear and tear but...