Observe connection assignment (DMX):
Connection
Contact
Wire colour
COM
1
Transparent
D+ (IN)
2
Red
D- (IN)
3
Black
D+ (OUT)
4
White
D- (OUT)
5
Blue
i
DMX ground (COM) shall always be insulated
against protection earth potential! A connection
of DMX ground and protection earth might cause
luminaire damage.
i
Use only data cables of type "Twisted Pair" with
120 ohms wave impedance.
i
Data cable shall always be provided with a
terminating resistor (R) at the last luminaire.
Connecting the luminaire (variant 'S')
WARNING!
Destruction of the plug contacts when
connecting or disconnecting the plug
under load.
Before connecting or disconnecting the
plug, disconnect the supply line.
The luminaire variant 'S' is fitted with the following
plug-in systems:
Mains: "Wieland gesis® RST20"
DMX: M12 circular connector
For connection use the cables and connectors listed
under "Accessories".
i
Please observe the technical documentation of
the "Wieland gesis
®
" plug-in system.
o
Wire the mains cable according to connection
diagram:
– Single connection with socket RST (9)
– Chain-linking with Y-Connector RST (11)
– Wiring with extension cable RST (12)
o
Wire the data cable according to connection
diagram:
– Input lead with connecting cable DMX (15)
– Luminaire connection with T-Connector DMX
(13)
– Chain-linking with extension cable DMX (14)
– Last luminaire with terminating resistor (R)
Figure 4: Connection diagram (variant 'S')
i
Due to a technical revision two different types of
connecting cables might be included in delivery
under art.-no. il LTGDXAL..(Figure 5).
Figure 5: Connecting cable V1 and V2
V1 Old version: WH and BU without function
V2 New version
Connecting the luminaire (variant 'S')
The luminaire variant 'L' is delivered with free cable
ends for mains- and data connection.
i
Connection terminals are not in scope of
delivery. Choose the terminals for connection of
the luminaire suitable for the used cable type
and according to national regulations (e.g. screw
terminals 2.5 mm² / 230 V / 16 A acc. to EN
60998-2-1). For connection of the DMX cables
use only terminals, that are approved for data
wiring.
i
The terminals must be provided with an
additional cover by the customer in order to
meet the requirements for double or reinforced
insulation as well as a degree of protection
suitable for the installation environment. Place
mains connection (A) and data connection (B)
into separate boxes (Figure 6).
o
Wire the luminaires according to connection
diagram.
Figure 6: Connection overview (variant 'L')
Figure 7: Connection diagram (variant 'L')
Beam direction with asymmetrical optics
Observe beam direction when using asymmetrical
optics (see device label):
Figure 8: Beam direction with asymmetrical optics
Aligning the luminaire (Figure 9)
Precondition: the retainer clamp is installed.
o
A:
Adjust luminaire housing in the clamp to the
desired angle of inclination.
o
B:
Attach clamping discs (3) to both sides of the
luminaire. To do this, tighten the screws in the
middle of the disc using a TORX 30 pin wrench.
o
C:
To lock the discs, also tighten the setscrews
(10) on both sides of the luminaire using an
INBUS 1.5 pin wrench.
Figure 9: Aligning the luminaire
Appendix
Technical data
Rated voltage
AC 220 ... 240 V ~
Mains frequency
50 / 60 Hz
Power factor
0.90
Power consumption
RGB
30 W
RGBW
32 W
TW
34 W
Degree of protection
IP 67
Protection class
I
Number of LEDs
12
Ambient temperature
-20 ... +35 °C
Dimensions L×W×H
500×70×164 mm
Weight
3.3 kg
Material (light)
Aluminium
Connection mode
Plug connector ('S'); Free
cable ends ('L')
Figure 10: Dimensioned drawing (mm)
Accessories
Figure 11
Warranty
We reserve the right to make technical and formal
changes to the product in the interest of technical
progress.
We provide a warranty as provided for by law.
Please send the unit postage-free with a description
of the defect to our central customer service office:
Insta GmbH
Service Center
Hohe Steinert 10
58509 Lüdenscheid
Germany