instalight 1065 R B RGB(W)/TW 500mm

Safety instructions

Electrical devices may only be mounted
and connected by electrically skilled
persons.

Serious injuries, fire or property damage
possible. Please read and follow manual fully.

Only the manufacturer may exchange the
connecting cable. In case of damaged
connection cable, send the luminaire to the
central customer service office of the
manufacturer.

Do not operate the luminaire on a conventional
dimmer. Use DMX control device for dimming.

If the protective glass is damaged, replace the
entire luminaire.

Do not damage the powder coating. A damaged
powder coating can lead to corrosion.

Chemicals may endanger the corrosion
protection. Avoid contact with aggressive media
(e.g. acids).

These instructions are an integral part of the
product, and must remain with the end customer.

Device components

Figure 1

(1) Luminaire housing

(2) Protective glass (Light output)

(3) Clamping disc

(4) Mains connecting cable

(5) Data connecting cable

(6) Retainer clamp

(7) Data connector

(8) Mains connector

Function

Intended use

Compact LED Facade spotlight. To accentuate
architectural elements in indoor and outdoor areas.
Suitable for wall, ceiling and floor mounting.

Light technology

RGB: 

12 LED light sources of different colours (4 x

red, 4 x green, 4 x blue). Each LED colour can be
controlled separately.

RGBW: 

12 LED light sources of different colours (3 x

red, 3 x greed, 3 x blue, 3 x white). Each LED colour
can be controlled separately.

TW: 

12 LED light sources (6 x warm white, 6 x cold

white). Each LED colour can be controlled
separately.

Beam characteristics dependant on choosen optics:
Asymmetrical, axially symmetrical or oval.

Beam angle and -characteristics see device label.

Control

Control of the individual light colors via DMX 512-A
(ANSI E1.11).

Parameterization via RDM (ANSI E1.20).

DMX channel mapping (RGB)

DMX channel

Description

1 (0...255)

Brightness red

2 (0...255)

Brightness green

3 (0...255)

Brightness blue

DMX channel mapping (RGBW)

DMX channel

Description

1 (0...255)

Brightness red

2 (0...255)

Brightness green

3 (0...255)

Brightness blue

4 (0...255)

Brightness white

DMX channel mapping (TW)

DMX channel

Description

1 (0...255)

Brightness warm white

2 (0...255)

Brightness cold white

DMX default settings

DMX start address*

1

Behaviour in case of
dmx data failure

The last received DMX
slot will be stored

*) Project-specific deviation possible. In this case the
default start address is marked on the luminaire.

Lamps / Maintenance

High-performance LED lamps. Average expected
lifespan (L80 / B10): 60,000 hours (@ 25 ° C).
The lamp may only be replaced by the manufacturer.
In case of damaged connection cable, send the
luminaire to the central customer service office of the
manufacturer. 

Cleaning

Before cleaning, switch the luminaire off and let it
cool down. Clean the luminaire housing with a
moistened soft towel.

The protective glass can be cleaned using the same
cleaning agents approved for use on glass-ceramic
cooktops.

Information for electrically skilled
persons

Fitting and electrical connection

DANGER!

Electrical shock when live parts are
touched.

Electrical shocks can be fatal.

Before connecting the luminaires,
disconnect the supply line.

Mounting the luminaire

o

To install the luminaire, first loosen the side
clamping discs (3) using a TORX 30 pin wrench
and remove the retainer clamp (5) from the
luminaire housing (1).

o

Fit boreholes (Figure 2).

i

Use both of the external holes in the retainer
clamp at least for the installation.

o

Fasten the retainer clamps (5) to the installation
substrate using two suitable screws.

o

Insert the luminaire housing (1) into the retainer
clamp (5).

o

Push on the clamping discs (3) on both sides of
the retainer clamp and hand-tighten the screw
using a TORX 30 pin wrench.

Figure 2: Drilling dimensions

Figure 3: Mounting the luminaire

Electrical connection – General Instructions

Observe the maximum number of luminaires (n)
per circuit:

Circuit breaker

max. number of
luminaires

B10

18

C10

30

B16

30

C16

50*

*) Max. related to data cable: 32

Observe connection assignment (mains):

Connection

Contact ('S')

Wire col. ('L')

External cond.

L

Brown

Neutral cond.

N

Blue

Protective
cond.

/

Green-yellow

0000000037
0000000037
29.03.2017

instalight 1065 R B RGB(W)/TW
500mm

Art. No.  il 1065 B...DX

Insta GmbH

Postfach 1830
58468 Lüdenscheid

T49  2351 936-0
www.insta.de
[email protected]

Operating instructions

Summary of Contents for instalight 1065 R B RGB/TW

Page 1: ...t Blau 4 0 255 Helligkeit Weiß DMX Kanalzuordnung TW DMX Kanal Beschreibung 1 0 255 Helligkeit Warmweiß 2 0 255 Helligkeit Kaltweiß DMX Werkseinstellung DMX Startadresse 1 Verhalten bei DMX Datenausfall Der zuletzt empfangene DMX Slot wird gespeichert Kann projektspezifisch vom Standard abweichen In diesem Fall ist die werkseitige Startadresse auf der Leuchte kenntlich gemacht Leuchtmittel Wartung...

Page 2: ...eitung und national geltenden Vorschriften auswählen z B Schraubklemmen 2 5 mm 230 V 16 A nach DIN EN 60998 2 1 Zum Anschluss der DMX Leitungen nur Klemmen verwenden die für Datenverkabelung zugelassen sind i Die Anschlussklemmen müssen bauseits mit einer zusätzlichen Umhüllung versehen werden so dass die Anforderungen an eine doppelte oder verstärkte Isolierung sowie eine der Montageumgebung ents...

Page 3: ... 0 255 Brightness white DMX channel mapping TW DMX channel Description 1 0 255 Brightness warm white 2 0 255 Brightness cold white DMX default settings DMX start address 1 Behaviour in case of dmx data failure The last received DMX slot will be stored Project specific deviation possible In this case the default start address is marked on the luminaire Lamps Maintenance High performance LED lamps A...

Page 4: ...uminaire suitable for the used cable type and according to national regulations e g screw terminals 2 5 mm 230 V 16 A acc to EN 60998 2 1 For connection of the DMX cables use only terminals that are approved for data wiring i The terminals must be provided with an additional cover by the customer in order to meet the requirements for double or reinforced insulation as well as a degree of protectio...

Reviews: