FOR
USE
BY
QUALIFIED
PERSONNEL
ONLY
Preventive Maintenance
Suggestions
The Avery Denninson heat seal machines are
relatively maintenance free. For long, trouble-free
life, the following preventive maintenance should be
followed:
1.
Do not heat seal items such as buttons, pins,
snaps, or zippers that tend to cut the silicone
rubber pad or scratch the Teflon heat platen.
2.
Periodically clean the Teflon-coated heat platen
with a non-abrasive piece of cloth. Stubborn
stains may be cleaned,
when platen is cool
,
with mineral spirits.
3.
When the heat platen is hot and not in use, keep
in open position (away from the silicone rubber
pad).
4.
To prevent soiling of substrate, periodic wiping of
the entire exterior machine, including platens,
with a clean rag is recommended. If necessary,
use mineral spirits for cleaning a
cold
machine.
Since mineral spirits are flammable, use
precautions and keep away from sparks, flame,
or hot heat platen.
5.
The machine requires periodic lubrication with a
high-temperature, non-melting grease
(MPPL023). Lubricate the post and heat platen’s
pivot pin depending upon usage. (Once every
month if used continuously.)
6.
Turn off air pressure when machine is not being
used.
NOTE
Wipe off any excess oil or grease.
8
WARNING
Power cord replacement
should be from the
manufacturer only (because it
requires a specially prepared
cord).
With the above items you should be able to
accomplish most repairs.
Replacement of Parts
Refer to the 3D explosive view and the bill of
materials at the end of this manual.
NOTE
Machines are shipped with a standard
air fitting. EUROPEAN models
include a MPPF086 quick
disconnect air fitting.
Micro Switch Adjustment
1.
Disconnect power supply; remove the top panel
of the instrument housing.
2.
Swing upper platen into working position until
stop is reached.
3.
The micro switch must be adjusted to JUST
CLOSE, as upper platen swings to this position.
4.
To change micro switch setting, loosen the
screw on slotted end of micro switch. Move in
desired direction to bring switch to
JUST
CLOSED
condition (listen for an audible click
from micro switch) and re tighten screw.
Airborne Noise Emission
Sound pressure level at operator station does not
exceed 70 dB(A).
General Maintenance
It is recommended that you have the following
items available:
A.Regular screw driver
B.Phillips head screw driver
C.Small adjustable wrench
D.Needle nose pliers with insulated handle
E.Set of Allen wrenches
F.Grease gun
G.Special high temperature grease MPPL023
Summary of Contents for 907
Page 1: ...MNL90000 Rev I 05 19 15 OPERATION AND MAINTENANCE MANUAL MODEL 907 ...
Page 13: ...FOR USE BY QUALIFIED PERSONNEL ONLY 12 907 Wiring Diagram 0412 ...
Page 14: ...FOR USE BY QUALIFIED PERSONNEL ONLY 13 ...
Page 17: ...FOR USE BY QUALIFIED PERSONNEL ONLY Notes 16 ...
Page 18: ...FOR USE BY QUALIFIED PERSONNEL ONLY 17 ...
Page 19: ...FOR USE BY QUALIFIED PERSONNEL ONLY ...
Page 20: ...FOR USE BY QUALIFIED PERSONNEL ONLY ...