40
8.1.2
No Display after Powering-on
Description:
After the power button on the front panel of the server was pressed, the power LED
on the front panel of the server lighted up. The chassis fan keeps rotating, but the
monitor had no display output.
Handling suggestion:
a.
Check whether the display is powered on properly.
b.
If the power-on is normal, but the display still has no display output, check
whether the display is properly connected to the server VGA port.
c.
If the VGA port is connected properly but the display still has no display
output, replace the display.
d.
If this still does not work, the VGA port may be abnormal. Log in to the BMC
Web GUI, and open the BMC remote KVM (for details, refer to
Firmware
Upgrade and Configuration
) to check whether the display is normal. If the
KVM can be displayed normally, the VGA port of the mainboard may be
abnormal. Please contact the customer service of Inspur. If the KVM cannot
be displayed normally, record the specific alarm information.
e.
If none of the preceding operations can resolve the problem, call Global
Service Hotline 1-844-860-0011 (toll-free)/1-760-769-1847 (DID) or email
us at
to inform the specific alarm and problem.
8.1.3
Status LED Alarm of the Front Panel
Description:
An LED on the front panel turned red to send an alarm.
Handling suggestion:
Determine which LED is abnormal according to the section Front Control Board
Buttons and LEDs.
a.
If the system fault LED is red, check whether the server is running normally.
If the server is running normally, log in to the BMC Web GUI to check the
BMC logs (for details, refer to
Firmware Upgrade and Configuration
) to
check whether there is an alarm. If yes, record the specific alarm
information.
b.
If the power fault LED is abnormal, check whether the power module LED
on the rear window of the server is abnormal (red or off). If the power
module LED is normal, log in to the BMC Web GUI to check the BMC logs
(for details, refer to
Firmware Upgrade and Configuration
) to check
whether there is an alarm. If there is an alarm, record the specific alarm