Chapter VIII System Power-on and Check
8.1
System power-on steps
Notes:
1. Before enabling disk array, it is required to connect power supply of all connected
extension cabinets, so as to guarantee the controller could recognize all connected extension
cabinets.
2. Wait at least 30 seconds to power on the main cabinet after enabling extension cabinet.
3. When storage array (main cabinet or extension cabinet) is connected to power supply, front
and rear indicators of storage array will flash intermittently.
4. Turn on all power switches on all extension cabinets connected to disk array.
5. Turn on two power switches of the main cabinet, according to different system
configurations, a complete system startup may need several minutes.
6. Check front and rear indicators of the main cabinet and extension cabinet, if there’s any
yellow indicator, record its position.
8.2
Disk array indicator description
Indicator
Signal
Position
Function
Power Supply
Left front panel
Chassis panel
On - The module is electrified
Off - The module is not electrified
Temperature
alarm
Left front panel
On - Temperature over high
Off - Temperature normal
Backup
power
indicator
Left front panel
On - Power backup status
Off - Power balanced status
Fault indicator
Left front panel
On - Part fault
Disk
array
positioning
Left front panel
On - Help to position part or
storage array location
Host
channel
speed
Controller
Host channel speed indicator
Left indicator on - 2Gb/s
Right indicator on - 4Gb/s
Both left and right indicators on -
8Gb/s
Cache activity
Controller
Displays cache activities
Flash - Data in cache
Off - No data in cache.
Summary of Contents for AS1100H
Page 1: ...Inspur Storage System AS1100H User Manual v1 0 Inspur ...
Page 26: ...Figure 6 4 Connect 3 Extension Cabinets Connect multiple extension cabinets ...
Page 27: ...Figure 6 5 Connect Multiple Extension Cabinets ...
Page 37: ...Figure 11 1 Setup page under AMW window as shown in the following figure Figure 11 2 ...