Inspire Ignire Wired Manual Download Page 11

BASIC FUNCTIONS (HOT WATER)

Off

Your hot water will be switched off.
Auto

Your hot water will follow your profile times

.

The default is: (This can be adjusted via your online account)

On between 06:00 and 08.30

On between 12:00 and 13:00

On between 18:00 and 20:00
Man

Your hot water will be switched on and will keep your hot water cyclinder at the temperature set

by your tank stat.
Boost

This is used if you would like to switch your hot water on for a set period of time.

The default is 1 hour. When pressed, ‘BOOST HW’ will flash to indicate that boost is currently

active.
Your hot water will switch on for the programmed length of time. After this time has expired, the

hot water function will return to the previous state.
Adjusting the Mode

Pressing the 'HW MODE' key will cycle through the above modes

.

Program Advance

This is used if you would like to ‘jump’ to the next scheduled hot water setting. Press the ‘ADV

HW’ key to ‘jump’ to the next setting in your schedule. It will only have an effect if the hot water

function is in auto mode. Pressing the ‘ADV HW’ key a 2nd time will cancel the program advance

and the unit will revert back to the current profile setting.

11

Summary of Contents for Ignire Wired

Page 1: ...Ignite Wired Heating Hot Water rev 2 0 www inspirehomeautomation co uk...

Page 2: ...core cable present at the Thermostat location If you cannot run a cable consider using our Ignite Wireless series Once installed your central heating and Hot Water can be switched on and off in respo...

Page 3: ...ns 103 x 103 x 45 mm max RADIO SIGNAL The Thermostat uses WiFi so you need a WiFi signal where the Thermostat is located You can use your phone to get a good indication of signal strength hold this ag...

Page 4: ...ge shows the path that the signal will travel to communicate between the Router and Thermostat This is an example of badly positioned items for the following reasons The signal travels between 2 exter...

Page 5: ...over single gang back boxes If this is not required it can be removed from the wallmount by twisting it anti clockwise Fig 1 Pull the thermostat away from the wall mount Fig 2 Finally remove the Wirin...

Page 6: ...following the appropriate circuit schematic for your heating system type ensuring that all wires are securely held and that no bare copper is visible outside the connector block For ease of wiring we...

Page 7: ...WIRING DIAGRAMS 7...

Page 8: ...G THE SYSTEM Thermostat must not have a Thermostat Radiator Valve TRV fitted to the radiator s ONLINE SETUP WIZARD You will need to be in the same location as the inspire system to complete the initia...

Page 9: ...9 YOUR THERMOSTAT Adjustment Keys Current Central Heaing Function WiFi Signal Strength Call for Heat Indicator Temperature Time Current Hot Water Function 9...

Page 10: ...BOOST CH will flash to indicate that boost is currently active Your heating will switch on for the programmed length of time at the programmed Boost Temperature If set After this time has expired the...

Page 11: ...t is 1 hour When pressed BOOST HW will flash to indicate that boost is currently active Your hot water will switch on for the programmed length of time After this time has expired the hot water functi...

Page 12: ...OOST HW keys simultaneously SETTING UP YOUR ACCOUNT Please check what version you have on the below list and follow the weblink for more information Residential www inspirehomeautomation co uk residen...

Reviews: