15
Property Damage
• Ensure that the control center voltage and phase match
the disposer motor and electrical supply. Check name-
plates on disposers and control centers for voltage and
phase specification.
• The disposer motor wiring connection is shown in the
disposer terminal box.
DANGER
Electrical Shock
• Turn off all electrical supply to the disposer before attempt-
ing any work on it. Use a voltmeter or circuit tester to
ensure power is off.
• Installation must conform to all local electrical codes.
• All control centers and disposers must be carefully and
permanently grounded.
• A properly fused disconnect must be installed at the electri-
cal supply source for the control center.
THREE PHASE MANUAL REVERSING SWITCHES
Manual Three Phase Reversing Switch -
With Time Delay Relay
Manual Three Phase Reversing Switch
Wiring Diagrams
460 volts
Three Phase
460 volts
Three Phase