Table of Contents

Introduction/Features
 Introduction ..................................................................................... 3
 Features .......................................................................................... 3

Mounting The Control Center/Plumbing Connections
 

Mounting the Control Center........................................................... 4

 

Plumbing Connections .................................................................... 4

Electrical Connection Diagrams .................................................................. 5

Electrical Connections .................................................................................. 6

Operating Instructions/AquaSaver Adjustment
 

Operating Instructions ..................................................................... 7

 

AquaSaver Adjustment ................................................................... 7

Troubleshooting ............................................................................................. 8

Wiring Diagrams
 

Model No. AS-101K-5 (120V, 1 phase, 1/2 - 2 HP) ......................... 9

 

Model No. AS-101K-6 (208/240V, 1 phase, 1/2 - 2 HP) ................ 10

 

Model No. AS-101K-7 (208/240V, 3 phase, 1/2 - 10 HP) .............. 11

 

Model No. AS-101K-8 (380/460V, 3 phase, 1/2 - 10 HP) .............. 12

Warranty

FOODSERVICE DISPOSER CONTROL CENTER LIMITED WARRANTY

InSinkErator Foodservice Disposer Control Centers are warranted against defects in material and workmanship for 
one year from the date of installation. The warranty includes parts and labor, provided the service is performed by an 
InSinkErator Factory Authorized Service Center. This warranty does not apply if failure is due to: faulty or improper 
electrical installation, faulty or improper plumbing installation, product abuse or misuse, or accidental damage.

Foodservice disposer accessories are included in this warranty only if they are included in the original disposer  
purchase package.

Summary of Contents for AQUASAVER AS-101K

Page 1: ...uses this appliance carefully reads and understands the Safety Instructions contained in this manual NOTICE is used to address practices not related to physical injury CAUTION indicates a hazardous si...

Page 2: ...odel No AS 101K 8 380 460V 3 phase 1 2 10 HP 12 Warranty FOODSERVICE DISPOSER CONTROL CENTER LIMITED WARRANTY InSinkErator Foodservice Disposer Control Centers are warranted against defects in materia...

Page 3: ...Erator Foodservice Disposers See Table 1 for approved disposer and control center combinations and Table 2 for electrical specifications The control center operates the disposer and control center com...

Page 4: ...cked separately The solenoid valve is supplied with a 24 V coil Make certain that the valves are plumbed according to the water flow direction arrows marked on the valve or the valves will not functio...

Page 5: ...und Lug Control Center Connection To Power Supply 4 5 6 7 Figure 4 Incoming 208 240 V Single Phase Line Power 24V Water Solenoid 1 GPM Flow Control 24V Water Solenoid 7 GPM Flow Control L1 L2 L3 L1 L2...

Page 6: ...ol center uses low voltage 24 V to operate contactor coils solid state control circuit push buttons and solenoid valves Red wires denote a 24 V circuit WATER SOLENOID VALVE Two 24 V solenoid valves ar...

Page 7: ...is completed Mid setting is approximately 45 seconds 2 With the disposer running at high water flow a Adjust the trip point control to maximum position the light is not illuminated b Turn the trip po...

Page 8: ...arding to avoid splashing and ejection of materials Do not put fingers or hands into the disposer When attempting to remove objects from a disposer use long handled tongs or pliers Turn power off befo...

Page 9: ...conform to local electrical codes All control centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the co...

Page 10: ...All control centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure...

Page 11: ...All control centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure...

Page 12: ...All control centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure...

Reviews: