PART 5 MAINTENANCE AND REPAIR PROCEDURES
SET
Specification
Factory Setting Multiplicator
P24
Simple door start (0:no/1:yes)
0
P25
Error management (1: activated/0: not activated, however the
safety criterias are activated)
1
P26
Automatic tank draining and refilling
2: yes if tank temp. is below 118° F
0: not activated
2
P27
Type of dosing unit for detergent
3: MP 28
5: “Fill/Water” terminal strip = Signal of water inlet valve
4: “Fill/Water” terminal strip = Signal while first tank filling
See “Combination of Buttons”
3
P32
With P32-37 you can control the Multifunction relay. To pro-
gram the relay see Service Manual 2
See technical doc. 2
to install
P38
EZEO (only with energy optimization plant on site)
0: inactive
1: tank heating is switched off
2: boiler heating is switched off
3: boiler and tank heating is switched off
4: machine in stand by mode (option)
0
P39
Type of dosing unit for rinse aid
2: MP 28
1: ELT 10
2
P44
Pressureless boiler is filled while final rinse (0: no/1: yes)
0
Parameter Set
®
C
1
2
3
A
B
4
5
7
8
6