PART 2 INSTALLATION INSTRUCTIONS
Commander 18-6 Technical Manual 2018
www.insingermachine.com 800-344-4802
13
®
Installation Drawing : Commander 18-6HC
INSTALLATION CONNECTIONS
LTR
DESCRIPTION
SIZE
H1
Hot Water to Final Rinse - 180
O
F
1/2” FIPS
H2
Hot Water to Remote Booster
1/2” FIPS
H3
Hot Water to Steam Booster
1/2” FIPS
H4
Hot Water to Built-In Booster
1/2” FIPS
S1
Steam to Tank
1/2” FIPS
S2
Steam to Steam Booster
1/2” FIPS
D
Drain Connection - Common
1 1/2” CU NOM
D1
Drain Cool Down Connection (Optional)
3/4” IPS
R1
Condensate Return - Steam Booster
1/2” FIPS
R2
Condensate Return - Tank Coil
3/8” FIPS
E1
Electric Service - Washer Motors & Built-In Booster
1 HP
E2
Electric Service - Remote Booster
6 kW
NOTES:
1.
Wash Tank is filled through Final Rinse Line
2.
Washer is field-convertible from Corner to Straight
configuration
**
12 kW when specified
**
*
REV F - 10/24/11
*
for ELECTRIC HEAT (3PH/60Hz), add the following:
208 V
240 V
380 V
480 V
Heat Element
5.0 kW
5.0 kW
5.0 kW
5.0 kW
Built-In Booster
10.1 kW 13.5 kW 13.5 kW 13.5 kW