3M 09/07
PRINTED IN USA
Information and specifications subject to change without notice
ADMIRAL 66-4
CSI
-
11400
* Note—Exhaust requirements are for pant leg connections only. For hood type, CFM requirements vary, consult hood manufac-
turer for specific sizing.
Note: For all rough in connections see Installation and Layout Detail Drawing.
SPECIFICATIONS
CONSTRUCTION -
Hood and tank constructed of 16 gauge type 304 S/S. Hood of all welded seamless construction. S/S frame,
legs, and feet. All internal castings are non-corrosive nickel alloy, bronze or S/S.
DOORS -
Two extra large die formed type 304 S/S front inspection doors riding in all S/S channels. No plastic or nylon sleeves or
liners used. Two intermediate S/S door safety stops on each door.
CONVEYOR -
One S/S roller chain conveyor, with rack driving lugs every sixth link, running along the front of the machine. 12 free
spinning rollers placed along the back wall of the machine. Conveyor accommodates all standard 20" racks. Conveyor drive system
includes direct drive gear motor with frictionless, trouble-free clutch system, spring-loaded and automatically re-engaging. Racks
conveyed automatically through washing and rinsing systems, powered by an independent 1/15 HP drive motor.
PUMPS -
Centrifugal type "packless" pump with brass petcock drain. Construction includes ceramic seal and a balanced cast
impeller on a precision ground stainless steel shaft. All working parts mounted as an assembly and removable as a unit without
disturbing pump housing. Two HP wash motor and 1/2 HP prewash motor: standard horizontal C-face frame, drip proof, internally
cooled with ball-bearing construction.
CONTROLS -
Top mounted NEMA 12 control enclosure, with 3.5 inch air gap between hood and enclosure, housing motor overload
protection, contactors, transformers, and all other dishwasher controls. All controls safe low voltage 24 VAC.
ENERGY SAVER -
Rack actuated lever automatically operates the final rinse solenoid only when a rack passes, saving water and
energy. The lever also activates an adjustable timer control. If no ware passes during the set time, the machine shuts down.
SPRAY SYSTEM -
Spray arms made of type 304 stainless steel pipe. Spray assemblies removable without the use of tools.
PREWASH -
One manifold above and one manifold below, each with 3 high pressure cleaning nozzles.
WASH -
Upper and lower manifolds with CrossFire
®
System (patented). One manifold above with 3 power wash arms, each with 5
high pressure cleaning slots and one manifold below with 4 power wash arms, each with 7 high pressure cleaning slots. The slots
are precision milled for water control producing a fan spray. Wash arms are fillet welded to the S/S manifold. The CrossFire
®
System
provides 4 horizontally spraying high pressure nozzles.
FINAL RINSE -
Three nozzles above and four nozzles below threaded into S/S schedule 40 pipes. Nozzle assemblies produce a fan
spray reducing water consumption, maximizing heat retention.
DRAINS -
Drain valves externally controlled. Overflow assembly with skimmer cap is removable without use of tools for drain line
inspection. Heaters protected by low water level control.
Capacity
per hour
Final rinse
consumption at
20 psi min.
* Exhaust
requirements
Peak rate
drain flow
Shipping
weight
Current draw
amps
Steam Gas
w/o booster
Electric
w/o booster
Tank capacity
Motor size
Electric usage
Final rinse
peak flow
at 20 psi min.
233 racks
5,825 dishes
225-500 meals
147 gals./hr.
0.63 gals./rack
350 CFM Load
350 CFM Unload
14 gals./min.
800 lbs.
9 gals. (prewash)
19 gals. (wash)
17 gals. (prewash-gas)
37 gals. (wash-gas)
2 hp (wash)
1/2 hp (prewash)
1/15 hp (conveyor)
15 kw tank
15 kw rem booster 40°rise
27 kw rem booster 70°rise
54 lbs./hr tank
52 lbs./hr booster 40° rise
91 lbs./hr booster 70° rise
50,000 BTUH
49 CFH nat. gas
20 CFH propane
3.3 gals./min.
Steam
consumption
at 20 psi min.
Gas
consumption
208/3/60 ............10.9 ..........11.6 ..............52.5
240/1/60 ............17.8 ..........17.8 ..............80.3
240/3/60 ............10.0 ..........10.7 ..............46.1
380/3/50 ..............6.0 ............6.4 ..............28.8
480/3/60 ..............5.0 ............5.3 ..............23.0
Installation distance from vertical
combustible service
2”