The steam generator has 3 connections.
1.
Steam Outlet:
Connect the white insulated hose to the tri
-
jet steam system within your shower as
shown in image
A.
Make sure these are fitted in the correct position as they are only attached for
transportation reasons only.
2.
Water Inlet:
When installing the water line for the steam generator, there are 3 options available:
•
Install a static water line from the shower valve (middle feed) to the steam generator.
•
Purchase Insignia
’
s WRAS approved braided hoses, however, you may require a male to male connector to
connect them together to make them long enough depending on your shower model (screwfix code: 71087)
•
Purchase a female blanking cap (screwfix code: 21851) which fits over the shower valve centre feed and
plumb a static line directly from the cold in to the steam generator water inlet.
3.
Drain
: Connect the grey rubber hose from the steam generators drain opening to the nozzle on the
shower waste as shown in image
B.
Secure in place with the use of the Jubilee clip (AMI01) found in
your screw pack Ensure you drill out the spigot to allow the steam generator water to drain in to the
waste.
Steam Generator Connections
(steam version only)
NOTE: MUST DRILL OUT
2
1
3
White Insulated Pipe
Tri
-
Jet Steam Outlet
A
B
Steam
Generator
Summary of Contents for INS0509
Page 5: ...www insigniashowers com Last Modified 11 02 2021 5...
Page 9: ...www insigniashowers com Last Modified 11 02 2021 9 Step 1 Level the Tray Twist to adjust...
Page 12: ...www insigniashowers com Last Modified 11 02 2021 12 x2 Step 4 Attach shelves and riser rail...
Page 18: ...www insigniashowers com Last Modified 11 02 2021 18 Step 10 Fit door handles...
Page 32: ...www insigniashowers com Last Modified 11 02 2021 32 Bathroom Electrical Zones...
Page 35: ...www insigniashowers com Last Modified 11 02 2021 35...