background image

 

www.insigniarange.com

 

Last Modified: 07/10/2014

 

 25 

Silicone Seal where shown in red on the inside of the shower

 

TESTING FOR WATER LEAKS

 

LEAVING SHOWER 24 HOURS AFTER BUILD ALLOWING SEALENT TO CURE

 

With all connections tight, the waste and hoses checked, jets fully sealed, your shower 

still around 18 inches from its designated final resting point and the silicone fully cured 

(hence leaving for 24 hours minimum) Switch on the overhead shower NOT the massage 

jets, remember these will fire water out at you and are not suitable for checking leaks as 

they would normally only operate when a person is in front of them. Just use COLD water 

setting as hot will make cabin misty and condensate thus the inspection becomes very  
difficult. Now on the OUTSIDE of the shower inspect each joint, factory seal, hose, clip 

and jet by walking from one side and going around to the back and then to the other side 

finishing at the front. If you have a small leak (normally caused through insufficient sealer 

or air bubble on assembly, dry the area thoroughly and reseal on the OUTSIDE. Please 

remember where you see the water this may not be exactly where the leak is as it could 

have run around to a low point. Never seal your inner fittings (accessories) inside unless 

you feel it necessary and make sure it is thin and neat, remember you will see this for the 

life of the shower! Again leave to cure and check. If all good now check shower functions 
i.e. jets for back massage,            foot massage, (if you have one) and finally hand show-

er, check your joints to these functions at the rear again. Never use the shower until 

all

 

checks have been made and the installer is 100% happy in the knowledge no leaks are 

present. 

 

All good?

 

Now push your shower FROM THE BASE NEVER GLASS OR FRAME into its final rest-

ing position. Now you can shower in the knowledge that you have no leaks a job done 

well and long product life. 

 

Happy showering!

 

Summary of Contents for GT9005

Page 1: ...ier s details and your postcode to hand before calling Replacements Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk WARRANTY REG NO __________________________ To claim your full 5 year warranty register your shower within 90 days of delivery at www insigniarange co uk...

Page 2: ...ical Requirements What s In The Boxes Screw Pack Contents Plumbing Requirements Starting The Installation Electric Box Connections Steam Generator Connections Sealing and Water Testing MK117 Control Panel Instructions Help Book Information Parts List 3 5 6 7 8 9 22 24 25 26 27 28 ...

Page 3: ...any years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your finish OUR BADGE RATING IN TERMS OF DIFFICULTY OF ASSEMBLY IS BASED ON CLIENT FEEDBACK 1 Badge Very easy 2 Badges Easy 3 Badges Moderate 4 Badges Harder than average 5 Badges Professional skills requi...

Page 4: ... WHEN YOUR ITEM IS ASSEMBLED ALWAYS USE THE SERVICES OF A FULLY QUALIFIED ELECTRICAL COMPANY TO COMPLETE CONNECTION FROM SHOWER TO HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID REGARDS ELECTRICAL ITEMS IF THIS IS NOT UNDERTAKEN YOURS AND OTHERS SAFETY IS PARAMOUNT NEVER ATTEMPT THIS YOURSELF REMEMBER These showers are designed to be free standing and movable from the...

Page 5: ...two methods 1 Connect within current laws and IP directives using plug and RCD provided with steam version or supply one for non steam version 2 Preferred Wire into isolated fused feed connecting directly to the house consumer service box Remove the fitted plug and ensure the Consumer unit has capabilities to replace RCD feature if RCD is removed Always use protection against electrical surge Your...

Page 6: ...ly how the unit is assembled When we use the word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit apart and carry out the final fix What s In The Boxes Tray Box 1x Tray 1x Roof Accessory Box Glass Room 2x Rear Door seals 2x Magnetic Door seals 2x Glass doors 2x fixed glass 2x ...

Page 7: ...eplacement missing parts can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Note In some cases you may have more screws than needed this is done so you have spares Product Code Description Quantity SP097 Door Handles 2 SP008 White Door Wheels 8 ST20 20mm Screws 20 ST35 35mm Screws 10 ST14 14...

Page 8: ...es Warranty is void if so as damage will occur If you have a combi supply please use a pressure reducing valve if required to lower the BAR pressure to the shower Please Remember that this product is free standing and is designed to be pulled away from the wall The water supply and waste require flexible pipes If you purchased the fitting kit with this shower you will have the required fittings Th...

Page 9: ...r transportation reasons therefore you will still need to ensure the correct sealing and alignment is carried out In the side of the waste supplied in the optional fitting kit you will notice a spigot not seen on an ordinary waste In most cases this is blanked yet should you have a steam version you need to gently drill this out as this item is for the steam generator drainage and will be connecte...

Page 10: ...ithout control panel using the ST20 screws Ensure you run a bead of silicone between the 2 panels and under the bottom of both panels Step 2 Attach the large back panel to the left column using the ST20 screws and again ensuring you run a bead of silicone between the 2 panels and under the large back panel ...

Page 11: ...0 screws and place a bead of silicone between the 2 panels and the tray Step 3 The next step is to attach the remaining column with control panel to back mirrored panel using the ST20 screws as shown in the picture to the left and again ensure a bead of silicone is placed between the panels and again under the bottom of the control panel ...

Page 12: ...e front fixed glass panels and cut any excess of if required Step 5 Attach both uprights to your top and bottom rails using the ST35 screws IMPORTANT If your front fixed glass has 2 black uprights pre fitted please bypass steps 6 and 7 Please note the wide upright is the outer upright and the cut out sits on the tray side ...

Page 13: ...panels into place by pushing them as per the arrows in the adjacent image Making sure the edge of the glass with the rubber seal fits into the grove tightly Using the ST14 Screws and the SW9 washers secure the uprights from the inside of the shower in to position You will need to do this for both the top and bottom of each column ...

Page 14: ...www insigniarange com Last Modified 07 10 2014 14 Step 8 Place and screw the upright curves into position using the ST20 screws and SW9 washers as indicated by the images ...

Page 15: ...position Now meet the front frame to the side panels as per the image and screw together using the ST25 screws and SW9 washers We recommend a bead of silicone is placed under the front frame to add to the rigidity of the shower and the overall sealing before finally securing it in position to aid with the sealing of the shower ...

Page 16: ...ange com Last Modified 07 10 2014 16 Step 10 Now align the roof to the glass panel and secure into position using the ST20 screws and repeat this process to fix the glass panels to the tray as indicated by the image ...

Page 17: ...f the bracket Accessory Installation Please Note Ensure all grey backing film on the rear of the glass panels are pierced through the existing glass holes with a knife to provide an efficient smooth fitting and location of the accessories We recommend using a screwdriver on the smaller holes Steam Pod Insert the pod from the inside of the shower and attach large white nut rom the rear x2 Foot Mass...

Page 18: ...our valve to the inner black tube using PTFE tape please note this only needs to be hand tight Over tightening will snap damage the inner black tube Thermostatic Probe Insert the chrome sleeve into the hole situated below the control panel and secure in place with the retaining nut Insert the rubber grommet into the sleeve and push the probe through from the rear of the cabin ensuring the probe pr...

Page 19: ...e wheels towards the track ensuring a secure a tight fit Now grease the track to ensure a smooth and long lasting operation not supplied Handles Ensuring that the inner thread is protruding out from the handle far enough place the handle on the outside of the door and secure by tightening the inner chrome knob to the protruding inner thread Door Seals Magnetic Seal Push the magnetic door seal on t...

Page 20: ...from then turn off the water and swap over the relevant hose Alternatively remove the outer chrome knob by removing the chrome cap and loosening the grub screw please ensure not to unscrew fully as this will drop within the chrome knob this is found on the opposite side to the chrome pillar Once you have succeeded in loosening this you can now slide your faceplate to correspond to the device Monso...

Page 21: ...m Last Modified 07 10 2014 21 Connecting up the water supply Left Valve Right Valve Requires 2 x 15mm equal T Valves Not Supplied The following set up is recommended for the water supply Cold Water Supply Hot Water Supply ...

Page 22: ...22 Electric Box Connections Connect the cables below to the corresponding devices on the shower Phono AUX CD MP3 Thermostatic Probe RJ11 Phone Connection Radio Aerial Fan Speaker Ozone o3 Top Light Tray Lights Requires supplied extension lead Earth ...

Page 23: ...se with more than one person unless the shower is designed for this This product is not to be used for washing bathing animals Connection For Tray Column Lights Using the supplied extension lead connect the end with the single connection to your tray lights Next bring the extension lead up the back of the shower and connect one of the plugs to the wire coming from the electric box representing the...

Page 24: ...r shower Make sure these are fitted in the correct position as they are only attached for transportation reasons only Water Inlet Connect a braided hose from the shower valve s centre feed to this opening Drain Connect the grey rubber hose from the steam generators drain opening to the nozzle on the shower waste as shown in the below image Steam Generator Connections ...

Page 25: ...g around to the back and then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area thoroughly and reseal on the OUTSIDE Please remember where you see the water this may not be exactly where the leak is as it could have run around to a low point Never seal your inner fittings accessories inside unless yo...

Page 26: ...ch Button 8 TUN Switch Between manual auto radio searching Button 9 Up Arrow Channel select up manual search up Button 10 Alarm Activate Alarm Button 11 M Set Steam Time Temperature When Radio is active this button will active the arrows to become volume buttons Button 12 Lock The control panel will automatically lock when not in use for a short time hold this button down for 3 seconds until a bee...

Page 27: ... contains many useful items such as is your parts warranty registered advice on cleaning servicing your shower cabin fault finding and many more items This is a MUST to read and not just HELP It saves time in nearly all cases avoiding contact with ourselves as most answers are there for a ready fix Simply visit www insigniarange co uk help aspx ...

Page 28: ...ndard shower head Sp166 Approximately 4 meters of U Style seals SP057 90 Degree Chrome Water Part Code Part Description SP300 Waste hose SP301 White insulated pipe SP221 Drain Hose SP183 MK117 Electric box SP232 Vertical steam generator SP308 Magnetic door seals SP310 Rear door seals SP173 3 port 3 feed thermo static valve for right hand column SP181 3 Port 2 feed thermo static valve for Left hand...

Page 29: ...e used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All images are registered with ImageTraker Insignia is a registered trademark of Maclean International Ltd ...

Reviews: