Inscape Data Link Power LPS2400 User Manual Download Page 3

Page | 3 
 

Safety Summary 

The following general safety precautions must be observed during all phases of operation of this 
instrument. Failure to comply with these precautions or with specific warnings elsewhere in this 
manual violates safety standards of design, manufacture, and intended use of the instrument. 
Inscape Data Corporation assumes no liability for the customer’s failure to 
comply with these requirements.  
 

Before Applying Power 

Verify that the product is set to match the available line voltage and all safety precautions are 
taken. 
 

Over Temperature Warning 

To prevent the switch from overheating, do not operate it in an area that exceeds the maximum 
recommended ambient temperature of (75°C). To prevent product cooling restriction, allow at 
least 3 inches (7.6 cm) of clearance around the product after installation. 
 

Ground the Instrument 

To minimize shock hazard, the instrument chassis and cabinet must be connected to an 
electrical ground. The instrument must be connected to the ac power supply mains through a 
three-conductor power cable, with the third wire firmly connected to an electrical ground (safety 
ground) at the power outlet. For instruments designed to be hard-wired to the ac power lines 
(supply mains), connect the protective earth terminal to a protective conductor before any other 
connection is made. Any interruption of the protective (grounding) conductor or disconnection of 
the protective earth terminal will cause a potential shock hazard that could result in personal 
injury.  
 
When installing the unit, always make the ground connection first and disconnect it last. 

 

Jewelry Removal Warning 

Before working on equipment that is connected to power lines, remove jewelry (including rings, 
necklaces, and watches). Metal objects will heat up when connected to power and ground and 
can cause serious burns or weld the metal object to the terminals. 

 

Do not Operate in Explosive Atmosphere 

Do not operate the product in the presence of flammable gases or fumes. 
 

 

Summary of Contents for Link Power LPS2400

Page 1: ...5 Inscape Data Corporation All Rights Reserved LinkPower AirEther AirGoogle and Inscape Data are trademarks of Inscape Data Corporation Disclaimer While every effort is made to ensure the information...

Page 2: ...cause harmful interference in which case the user will be required to correct the interference at his own expense The user is cautioned that changes and modifications made to the equipment without app...

Page 3: ...chassis and cabinet must be connected to an electrical ground The instrument must be connected to the ac power supply mains through a three conductor power cable with the third wire firmly connected t...

Page 4: ...lightning activity Comply with Local and National Electrical Codes Installation of the equipment must comply with local and national electrical codes Do Not Exceed Input and Output Ratings Do not oper...

Page 5: ...ncy UPS Input 8 Switch Control Panel 8 Top Cover 8 PoE Switch Internal View 9 LED Indicator Description Table 9 Connector Layout Diagram 10 Waterproof Ethernet Fiber Optics Power Connector Assembly Di...

Page 6: ...Wall Mounting Kit 1 AC Power Cable with one 3 PIN AC Power Connector one Coupler 1 DC Power Cable with one 4 PIN AC Power Connector one Coupler 1 Optional Please contact Inscape Data via sales inscape...

Page 7: ...5 8 8G backplane bandwidth 6 1K MAC address table 7 Its 3KV network port surge protection can adapt to harsh outdoor environment Under the temperature of 40 75 C working at a full load 240W 8 The 2 g...

Page 8: ...er the actual power required will be based on the total power consumption fo the connected devices For example if there are two high power devices with 60W each and two low power devices with 10W each...

Page 9: ...or current overload OFF No Connected PD or Power OFF 1000MIndicator Network Link OFF No Connected PD or Power OFF Yellow LED Blink Data transmission properly Yellow LED ON Connected with 1000Mbps netw...

Page 10: ...vides the following way to ground the equipment for safety and protection of the system It is highly recommended that you re to perform both grounding procedures for maximum safety and protection of y...

Page 11: ...UNDER WARRANTY U S POWER CORD POWER CORD FOR OUTSIDE OF U S GREEN COLOR WIRE MUST BE GROUNDED 6 FT AC Power Cord White W AC L Green G Ground Black B AC N AC Power Cable 1 White W AC N 2 Green G Groun...

Page 12: ...Page 12...

Page 13: ...ite http www inscapedata com U S Headquarters Here s how to reach us if you d like to place an order or if you have questions concerns or need support Telephone Postal Mail North and South America Cus...

Reviews: