Waterproof Ethernet, Fiber Optics, & Power Connector Assembly
Diagram
Plastic Plug
Note:
The Sealing Insert comes with one and three holes. The Plastic Plugs
MUST
be used to cover the Sealing Insert, if
any of the hole is not used in order to maintain waterproof of the connector.
IP Management Login (Managed Models Only):
All network ports of this device support WEB management equipment, IP management by default 192.168.2.1,
subnet mask: 255.255.255.0, the default gateway: 192.168.2.254. The administrator of the PC as long as you can
communicate with the equipment management.
Default IP Address:
192.168.2.1
Default login user:
“admin” and login password: “system”.
To Download Web Management Manual Online:
https://www.inscapedata.com/pdf/LPS1800_Web_Management_ManualV2.0.pdf
Grounding Protection:
The system provides the following way to ground the equipment for safety and protection of the system. It is
hi
ghly recommended that you’re to perform both grounding procedures for maximum safety and protection of
your equipment. However, at least of the grounding MUST be performed, otherwise any product damage caused
by improper or no grounding will not be covered under warranty.
Grounding the Switch by Using the AC Power Cord
You MUST ground the switch through the AC wire of the power cord. Please make sure that:
1.
The GREEN COLOR WIRE of the power cord extension is used as a PE (Protective Earth) terminal, Figure 5,
Aka, Equipment Grounding Conductor
MUST BE CONNECTED TO A GROUND CONTACT IN A POWER
OUTLET
.
2.
The power cord is securely connected to the power outlet at the premise.
3.
The ground contact in the power outlet is securely connected to the ground in the power distribution
room or on the AC transformer side.
4.
If the ground contact in the power outlet is not connected to the ground, report and resolve the problem
and reconstruct the grounding system.
NOTE:
P
RODUCT DAMAGE CAUSED BY IMPROPER OR NO GROUNDING WILL NOT BE COVERED UNDER WARRANTY
!