Inscape Data Link Power LPS1800-T1 User Manual Download Page 8

Page | 8 
 

Waterproof Ethernet, Fiber Optics, & Power Connector Assembly 

Diagram 

 

 

 

 

Plastic Plug 

Note: 

The Sealing Insert comes with one and three holes.  The Plastic Plugs 

MUST

 

be used to cover the Sealing Insert, if 

any of the hole is not used in order to maintain waterproof of the connector. 

 

IP Management Login (Managed Models Only): 

All  network  ports  of  this  device  support  WEB  management  equipment,  IP  management  by  default  192.168.2.1, 
subnet mask: 255.255.255.0, the default gateway: 192.168.2.254. The administrator of the PC as long as you can 
communicate with the equipment management.

 

Default IP Address: 

192.168.2.1

 

Default login user:  

“admin” and login password: “system”.

 

To Download Web Management Manual Online:

 

https://www.inscapedata.com/pdf/LPS1800_Web_Management_ManualV2.0.pdf

 

Grounding Protection: 

The system provides the following way to ground the equipment for safety and protection of the system.  It is 
hi

ghly recommended that you’re to perform both grounding procedures for maximum safety and protection of 

your equipment.  However, at least of the grounding MUST be performed, otherwise any product damage caused 
by improper or no grounding will not be covered under warranty. 

Grounding the Switch by Using the AC Power Cord 

You MUST ground the switch through the AC wire of the power cord.   Please make sure that: 

1.

 

The GREEN COLOR WIRE of the power cord extension is used as a PE (Protective Earth) terminal, Figure 5, 
Aka, Equipment Grounding Conductor 

MUST BE CONNECTED TO A GROUND CONTACT IN A POWER 

OUTLET

2.

 

The power cord is securely connected to the power outlet at the premise. 

3.

 

The ground contact in the power outlet is securely connected to the ground in the power distribution 
room or on the AC transformer side. 

4.

 

If the ground contact in the power outlet is not connected to the ground, report and resolve the problem 
and reconstruct the grounding system. 

NOTE:

 

P

RODUCT DAMAGE CAUSED BY IMPROPER OR NO GROUNDING WILL NOT BE COVERED UNDER WARRANTY

Summary of Contents for Link Power LPS1800-T1

Page 1: ...ght 2015 Inscape Data Corporation All Rights Reserved LinkPower AirEther AirGoogle and Inscape Data are trademarks of Inscape Data Corporation Disclaimer While every effort is made to ensure the infor...

Page 2: ...at changes and modifications made to the equipment without approval of the manufacturer could void the user s authority to operate this equipment The manufacturer is not responsible for any radio or T...

Page 3: ...chassis and cabinet must be connected to an electrical ground The instrument must be connected to the ac power supply mains through a three conductor power cable with the third wire firmly connected t...

Page 4: ...equipment must comply with local and national electrical codes Do Not Exceed Input and Output Ratings Do not operate the product to exceed the power input and output ratings This product Conforms to t...

Page 5: ...et Fiber Optics Power Connector Assembly Diagram 8 IP Management Login Managed Models Only 8 Grounding Protection 8 Grounding the Switch by Using the AC Power Cord 8 Power Redundancy UPS Input 9 RESET...

Page 6: ...power up to 25 5W per IEEE802 3at standard Supply power for powered devices compatible with IEEE802 3at 5 Support IEEE802 3x full duplex flow control and duplex backpressure flow control 6 8 8G backp...

Page 7: ...10 100M Indicator Link OFF No Connected PD or Power OFF Yellow LED Blink Data transmission properly Yellow LED ON Connected with 10Mbps or 100Mbps network device OFF No connected PD L A Indicator Link...

Page 8: ...tion of the system It is highly recommended that you re to perform both grounding procedures for maximum safety and protection of your equipment However at least of the grounding MUST be performed oth...

Page 9: ...WIRE of the AC DC Power Cords Is Used for Grounding Power Redundancy UPS Input The switch offers dual power redundancy i e AC DC input There are two power inputs as shown below diagram When the AC in...

Page 10: ...3 13A DC power Please note the DC Power Cord Kit Part WPCK 004 is an optional accessory RESET Switch System Reset Managed Models Only There are two ways to reset the system i e software reset and hard...

Page 11: ...Page 11 Installation Mounting You can mount the system with one of the two ways 1 Wall Mount Wall Mount Kit Standard Accessory 2 Pole Mount Optional Accessory MMK001 Pole Mount Kit...

Page 12: ...Page 12 Product Dimensions Wall Mount Pole Mount...

Page 13: ...Page 13 Appendix I Technical Specifications ELECTRICAL PIN OUT DIAGRAM...

Page 14: ...nscapedata com U S Headquarters Here s how to reach us if you d like to place an order or if you have questions concerns or need support Telephone Postal Mail North and South America Customer Service...

Reviews: