background image

TECHNICAL DOCUMENTATION

6

www.inpower-sys.com 

  

                           1IPSE1A33-60

K

EY

 D

ATA

5. 

Parameter

Symbol

Value (at +25°C)

Max. collector-emitter voltage

V

CE

3300V

Input supply voltage range

V

DC

+14 to +30V

Output voltage: ON/OFF voltage

V

ON/VOFF

±15V

Isolation testing voltage (V

AC 

RMS 50Hz / 1 min)

V

ISOL

6000V

Switching frequency (max.)

f

S max

120kHz

Peak output current

I

G

±70A

Peak output power

P

DC/DC

3W

Quiescent current typically

I

DC

0.25A (at 15V)

Max. input current at max. load

I

DC max

0.50A (at 15V)

Coupling capacitance primary/secondary side (max.)

C

io

2pF

Switching frequency of isolated converter

f

SMPC max

0.5MHz

Creepage distance

>30mm

Frequency of logic controller

f

20MHz

Operating temperature (measured on driver surface)

T

OP

-40 to +85°C

Storage temperature

T

ST

-40 to +85°C

Input driving and output error signal

optical

660nm

Turn-on delay time

t

pdON

 400nsec

Turn-off  delay time

t

pdOFF

400nsec

Typical time of soft shut down

t

SSD

1-2μsec

Max. system time between fault detection and error notifi cation

t

SYS

100nsec

Time between detection of desaturation and gate voltage falling edge

t

pDES

300nsec

I

NTERFACES

6. 

Interface

Part Type

Remarks

Optical Receiver

HFBR-2531Z (Avago)

For suitable connectors see
www.avagotech.com

Optical Transmitter

HFBR-1531Z (Avago)

DC supply on PCB

FKC 2,5/2-STF-5,08 (Phoenix )

Connector: MSTBV 2,5/2-GF-5,08 (Phoenix)

C

ABLE

 L

ENGTH

7. 

Max. length of coaxial cable: 30cm. Max. length of simple cable: 7cm. 
For gate and auxiliary emitter connections use coaxial cable RG58 C/U with auxiliary emitter connected 
to the shielding. For power emitter and auxiliary collector it is recommended to use HV isolation cable, for 
instance Radox 9 GKW-AX, 1.5mm2.

Summary of Contents for 1IPSE1A33-60

Page 1: ...E1A33 60 FOR MEDIUM AND HIGH POWER IGBTS M A N U A L InPower Systems GmbH Am Kornfeld 11 D 86932 P rgen Germany Tel 49 0 8196 93000 Fax 49 0 8196 930020 Email info inpower sys com VAT Id DE 221021830...

Page 2: ...m i n a r y 2 TABLE OF CONTENTS 1 SAFETY NOTICE 3 2 HANDLING AND MOUNTING ADVICES 4 3 MAIN FEATURES 5 4 MECHANICAL DIMENSIONS 5 5 KEY DATA 6 6 INTERFACES 6 7 COMMISSIONING SUPPORT 7 8 INPUTS AND OUTPU...

Page 3: ...te handling or transport Contact while uninstalled is permitted only with ESD protection Install only without supply voltage Use only suitable electronic devices Always keep sufficient safety distance...

Page 4: ...not exceed 30cm Max length of simple cable should not exceed 7cm For the gate and auxiliary emitter connections it is recommended to use coaxial cable RG58 C U with auxiliary emitter connected to the...

Page 5: ...er current in all short circuit conditions over voltage during turn off Advanced control and protection functions four level desaturation monitoring two level di dt monitoring feedback clamping with a...

Page 6: ...rage temperature TST 40 to 85 C Input driving and output error signal optical 660nm Turn on delay time tpdON 400nsec Turn off delay time tpdOFF 400nsec Typical time of soft shut down tSSD 1 2 sec Max...

Page 7: ...n the DC low voltage supply for the driver Make sure that there is no strange noise smell heat or otherwise originating from the driver The voltage supply LEDs should now light up green which means th...

Page 8: ...capture the input and output signals on the oscilloscope and save the images If all is well you have got the system working correctly If something does not seem right stop the test straight away and c...

Page 9: ...nting holes for M4 screws It is possible to use plastic or metal screws Mounting holes have different potentials The auxiliary adaptation board is including an addi tional gate capacitor C3 C2 or C1 i...

Page 10: ...le connector Driver with cable connector Max length of coaxial cable 40cm For gate and auxiliary emitter connections use coaxial cable RG58 C U with auxiliary emitter connected to the shielding For po...

Page 11: ...ons use coaxial cable RG58 C U with auxiliary emitter connected to the shielding For power emitter and auxiliary collector it is recommended to use HV isolation cable for instance Radox 9 GKW AX 1 5mm...

Page 12: ...minal operation red light U sat 1 protection was operating U sat 2 D 17 no light system is working in nominal operation red light U sat 2 protection was operating U sat 3 D 18 no light system is worki...

Page 13: ...e described hardware has been checked Discrepancies may exist nevertheless no guaranty is assumed for total congruence The information contained in this document is subject to regular revision Any alt...