5.
Parameter
Symbol
Value (at +25°C)
Max. collector-emitter voltage
V
CE
3300V
Input supply voltage range
V
DC
+14 to +30V
Output voltage: ON/OFF voltage
V
ON/VOFF
±15V
Isolation testing voltage (V
AC
RMS 50Hz / 1 min)
V
ISOL
6000V
Switching frequency (max.)
f
S max
120kHz
Peak output current
I
G
±70A
Peak output power
P
DC/DC
3W
Quiescent current typically
I
DC
0.25A (at 15V)
Max. input current at max. load
I
DC max
0.50A (at 15V)
Coupling capacitance primary/secondary side (max.)
C
io
2pF
Switching frequency of isolated converter
f
SMPC max
0.5MHz
Creepage distance
>30mm
Frequency of logic controller
f
20MHz
Operating temperature (measured on driver surface)
T
OP
-40 to +85°C
Storage temperature
T
ST
-40 to +85°C
Input driving and output error signal
optical
660nm
Turn-on delay time
t
pdON
400nsec
Turn-off delay time
t
pdOFF
400nsec
Typical time of soft shut down
t
SSD
1-2μsec
Max. system time between fault detection and error notifi cation
t
SYS
100nsec
Time between detection of desaturation and gate voltage falling edge
t
pDES
300nsec
I
NTERFACES
6.
Interface
Part Type
Remarks
Optical Receiver
HFBR-2531Z (Avago)
For suitable connectors see
www.avagotech.com
Optical Transmitter
HFBR-1531Z (Avago)
DC supply on PCB
FKC 2,5/2-STF-5,08 (Phoenix )
Connector: MSTBV 2,5/2-GF-5,08 (Phoenix)
C
ABLE
L
ENGTH
7.
Max. length of coaxial cable: 30cm. Max. length of simple cable: 7cm.
For gate and auxiliary emitter connections use coaxial cable RG58 C/U with auxiliary emitter connected
to the shielding. For power emitter and auxiliary collector it is recommended to use HV isolation cable, for
instance Radox 9 GKW-AX, 1.5mm2.