ED. 2009/11
Start-up
11
4.
Start-up
The start-up of the valve can be carried out provided the instructions indicated in Chapter 3 –
Receiving and Installation
are
followed.
This equipment is suitable for his use in food process.
4.1.
SINGLE-SEAT VALVE APPLICATIONS.
Single-seat valves may be cut-off or change-over type. Cut-offs are used to open and close the passage of fluid, whereas
change-overs are used to redirect the flow trajectory.
4.2.
START-UP.
Before start-up, the responsible persons should be duly informed of the operation of the valve and
the safety instructions to be followed. This instruction manual should be available to personnel at all
times.
The following should be taken into consideration before starting-up the valve/actuator;
•
Check that the pipe and valve are completely free from any traces of welding or other foreign matter. Carry out the
cleaning of the system if required.
•
Verify the smooth operation of the valve. If necessary, lubricate with special grease or soapy water.
•
Check for possible leaks and check that all the pipes and connections are watertight and free from leaks.
•
If the valve is supplied with actuator, ensure that the alignment of the valve shaft with the actuator shaft allows for a
smooth operation.
•
Check that the compressed air pressure at the intake to the actuator is that indicated in the Technical Specifications
(
Chapter 8
).
•
Mind the quality of the compressed air according to the specifications described in chapter 8 Technical Specifications.
•
Operate the valve.
4.3.
OPERATION.
Do not modify the operating parameters for which the valve has been designed without written prior
authorisation from INOXPA.
Do not touch the moving parts of the coupling between the actuator and the valve when the
actuator is connected to the compressed air.
Danger of burns! Do not touch the valve or pipes when hot liquids are circulating or when cleaning
and/or sterilisation are being carried out.
www.sks-online.com